DC-DC / Intermediate Bus Converter
Description
Embedded Power for Business-Critical Continuity
Quarter-Brick Series
Fixed Ratio 2nd Generation IBC
Total Power: 600W Input Voltage: 38 - 55VDC
Rev.
03.
31.
09_162 Quarter-Brick Fixed IBC60 of 4
Special Features
• 48 V input with isolated 9.
6 V output • Ultra-high efficiency, 97% • Unprecedented usable output power levels • High power density open-frame technology • Wide operating ambient temperature range • DOSA quarter-brick high current footprint and pinout • Low profile, 0.
48” (12.
2 mm) • Meets basic insulation requirements of EN60950-1 • Remote ON/OFF and overtemperature protection • RoHS compliant • 2 Year Warranty
Electrical Specifications
Input
Input voltage range: Input current: Input current (max.
): Input reflected ripple: Remote ON/OFF Logic compatibility ON OFF: Undervoltage lockout: Start-up time: (See Note 3) Power up Power down Power up Remote ON/OFF Low line to high line Full load to min.
load Remote OFF (See Note 1) (See Note 4) 38-55 Vdc 6.
5 mA typ.
13 A max.
@ lo max.
and Vin = min.
rated 1200 mA (pk-pk) 35 mA rms (See Note 6) Open collector ref.
to -Input > 2.
4 Vdc < 0.
4 Vdc 34.
5 V 33 V 11rms 2 rms See table See Table 7.
0 - 11.
0 Vdc 0A At turn-on and turn-off (See Note 2) None None 100 mV pk-pk typ.
20 mV rms typ.
Output
Line regulation: Load regulation:
Total error band: Vin = 38 V to 55 V (including setpoint, line, load and temperature)
Safety
• UL/cUL : CAN/CSA 22.
2 No.
60950-1 : UL60950-1 File No.
E135734 • VDE File No.
10401-3336-0206 Licence No.
40012752
Minimum load: Overshoot: Undershoot: Ripple and Noise: 5-20 MHz
All specifications are typical at nominal input, full load at 25 °C ambient unless otherwise stated
Embedded Power for Business-Critical Continuity
Electrical Specifications Continued
EMC Characteristics
Immunity: ESD air enclosure: Input transients: EN61000-4-2 8 kV, 6 kV Input voltage > 59 V > 60 V > 62 V Air, contact Duration before shutdown 2 Seconds 1 Second 0 Seconds 97% Input/outp...