Single Phase Glass Passivated Silicon Bridge Rectifier
Single Phase Glass Passivated Silicon Bridge Rectifier
DB105G thru DB107G
VRRM = 600 V - 1000 V IO = 1 A
Features • Id...
Description
Single Phase Glass Passivated Silicon Bridge Rectifier
DB105G thru DB107G
VRRM = 600 V - 1000 V IO = 1 A
Features Ideal for printed circuit board Reliable low cost construction utilizing molded plastic technique High surge current capability Small size, simple installation Types from 600 V up to 1000 V VRRM Not ESD Sensitive
Mechanical Data Case: Molded plastic Terminals: Plated terminals, solderable per MIL-STD202, Method 208 Polarity: Polarrity symbols marked on the body Mounting position: Any
DB Package
Maximum ratings at Tc = 25 °C, unless otherwise specified
Parameter
Symbol
Conditions
Repetitive peak reverse voltage RMS reverse voltage DC blocking voltage Operating temperature Storage temperature
VRRM VRMS VDC
Tj Tstg
DB105G
600 420 600 -55 to 150 -55 to 150
Electrical characteristics at Tc = 25 °C, unless otherwise specified Single phase, half sine wave, 60 Hz, resistive or inductive load For capacitive load derate current by 20%
Parameter
Symbol
Conditions
DB105G
Maximum average forward rectified current
Peak forward surge current
Maximum instantaneous forward voltage drop
Maximum DC reverse current at rated DC blocking voltage
Typical junction capacitance Typical thermal resistance
IO IFSM VF
IR Cj RΘJC
Ta = 40 °C tp = 8.3 ms, half sine
IF = 1.0 A
Ta = 25 °C Ta = 125 °C
1.0
30
1.1
5 500 25 20
DB106G
800 560 800 -55 to 150 -55 to 150
DB107G
1000 700 1000 -55 to 150 -55 to 150
DB106G
1.0 30
1.1
5 500 25 20
DB107G
1.0 30
1.1
5 500 25 2...