CONTACTOR
ENGINEERING DATA SHEET
7401-4658
CONTACTOR 1PST-DM, 400 AMP
Non latching solenoid design power contactor
Qualified to...
Description
ENGINEERING DATA SHEET
7401-4658
CONTACTOR 1PST-DM, 400 AMP
Non latching solenoid design power contactor
Qualified to
MIL-PRF-6106 MS24185-D1 AN-3380-1
PRINCIPLE TECHNICAL CHARACTERISTICS
Contacts rated at
400 Amps / 28 Vdc
Weight
1180g max.
Dimensions of case
139.7mm x 62mm x 44.3mm max.
Special units available upon request.
APPLICATION NOTES: 101 102 103G 007
CONTACT ELECTRICAL CHARACTERISTICS
Minimum operating cycles
Contact rating per pole and load type
50,000 cycles 50,000 cycles 50,000 cycles
resistive inductive (L/R=5ms) motor
50,000 cycles
minimum current (Amps)
Load Current in Amps @28Vdc
400 100 400
40
Featuring LEACH© power and control solutions www.esterline.com
AMERICAS 6900 Orangethorpe Ave. P.O. Box 5032 Buena Park, CA 90622 . . Tel: (01) 714-736-7599 Fax: (01) 714-670-1145
EUROPE 2 Rue Goethe 57430 Sarralbe France . . Tel: (33) 3 87 97 31 01 Fax: (33) 3 87 97 96 86
ASIA Units 602-603 6/F Lakeside 1 No.8 Science Park West Avenue Phase Two, Hong Kong Science Park Pak Shek Kok, Tai Po, N.T. Hong Kong Tel: (852) 2 191 3830 Fax: (852) 2 389 5803
Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component.
Date of issue: 6/06
- 153 -
Page 1 of 4
COIL CHARACTERISTICS (Vdc)
Nominal operating voltage Maximum operating voltage Maximum pick-up voltage Maximum drop-out voltage Coil resistance in Ohms ±10% at +25° C
GENERAL CHARACTERISTICS
Temperature range Dielectric strength at ...