Document
[ 2 YEAR WARRANTY ]
NAL40 and NAN40 SERIES
Single, dual and triple output
• 5.0 x 3.0 x 1.2 inch package (1U applications) • Ideal for high volume designs • Industry standard package • Overvoltage and short circuit protection • 40W with free air convection • NAN40: EN55022, EN55011 conducted emissions level B • NAL40: EN55022, EN55011 conducted emissions level A
The NAL40 and NAN40 series are 40W universal input AC/DC power supplies on a 5 x 3 inch card with a maximum component height of 1.2 inch for use in 1U applications. These series are available with a wide range of models in the industry standard 5 x 3 inch footprint at low cost making the series ideal for new and existing high volume communication and industrial applications. The difference between the NAL40 and NAN40 is their conducted emissions performance - the NAN40 meets EN55022 level B while the NAL40 meets level A. The NAL40 and NAN40 provide 40W of output power with free air convection cooling with a peak output of 50W for a maximum duration of 60 seconds. The NAL40 and NAN40 series are designed for use in high volume low power data networking, computer and telecom applications such as hubs, routers, POS terminals, cable modems and PABX's. This list is not exclusive as the generic feature set of both series with industry standard output configurations provide a solution for most high volume applications including many industrial applications.
SPECIFICATION All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
Line regulation
Main output Auxiliary outputs
±0.5% ±1.0%
Total regulation
Main output Auxiliary outputs
±3.0% ±5.0%
Overshoot/undershoot At turn-on
<10%
Transient response
+5.1V
±150mV max. dev.,
(1.5A to 3A step)
500µs recovery
Temperature coefficient
±0.02%/°C
Overvoltage protection +5.1V output
6.25V ±0.75Vout
Output power limit
Primary power limited
50W Pout, min. 110W Pin, max.
Short circuit protection Multiple output
Single 12V, 15V, 24V and 48V
30 seconds
Continuous automatic recovery
Output voltage trim
NAN40-7662 only ±5% (See Note 10)
INPUT SPECIFICATIONS
Input voltage range
Universal input
90 to 264VAC 120 to 370VDC
Input frequency range
47Hz to 440Hz
Input surge current
110VAC, cold start 230VAC, cold start
15A 32A
Safety ground leakage current
110VAC, 60Hz 230VAC, 50Hz
0.2mA 0.4mA
International Safety Standard Approvals
VDE0805/EN60950/IEC950/IEC1010 File No. 10401-3336-1076 Licence No. 70567, 1076 and 90354
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
Certificate No. PS/605108
PAGE 22
EMC CHARACTERISTICS
Conducted emissions Conducted emissions Radiated emissions ESD air ESD contact Surge Fast transients Radiated immunity Conducted immunity
NAL: EN55022, FCC part 15 level A
NAN: EN55022, FCC part 15 level B
EN55022, FCC part 15
level A
EN61000-4-2, level 3 Perf. criteria 2
EN61000-4-2, level 4 Perf. criteria 2
EN61000-4-5, level 3 Perf. criteria 2
EN61000-4-4, level 3 Perf. criteria 2
EN61000-4-3, level 3 Perf. criteria 2
EN61000-4-6, level 3 Perf. criteria 2
GENERAL SPECIFICATIONS
Hold-up time
110VAC 230VAC
10ms @ 40W 60ms @ 40W
Efficiency
68% min. @ 40W
Isolation voltage
Input/output Input/chassis
3000VAC 1500VAC
Switching frequency
Variable
Approvals and standards (See Note 9)
VDE0805, EN60950, IEC950 BABT, IEC1010, UL1950 CSA C22.2 No. 950
Weight
200g (7.06oz)
MTBF
MIL-HDBK-217F
150,000 Hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating Non-operating
0°C to +70°C -40°C to +85°C
0°C to 50°C ambient, convection cooled
40W
50°C to 70°C,
Derate linearly
ambient conv. cooled
to half load
Peak (0°C to 50°C) max. 60s
50W
Relative humidity
Non-condensing
5% to 95% RH
Altitude
Operating Non operating
10,000 feet max. 30,000 feet max.
Vibration
Three orthogonal axes,
2.4G rms
random vibration, 10 5Hz to 500Hz
minute test for each axis
Data Sheet © Artesyn Technologies® 2001
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES | 40W AC/DC
40 Watt AC/DC universal input switch mode power supplies
OUTPUT VOLTAGE
MAX (1)
OUTPUT CURRENT PEAK (2)
FAN (3)
TOTAL RIPPLE (4)
REG. (5)
MODEL NUMBER (B)
+ 5.1V (IA) +12V (IB) –12V (IC)
+5.1V
3A 2A 0.35A 3A
7A 3A 1A 7A
4A 2A 0.5A 4A
50mV 120mV 120mV 45mV
±3.0% ±5.0% ±5.0% ±3.0%
NAL40-7608 (5) NAN40-7608 (5) NAN40-7662 (10)
NAL40-7628 (8) NAN40-7628 (8)
1
+12V
0.35A
3A
0.5A
110mV ±5.0%
–12V
0.35A
1A
0.5A
110mV ±5.0%
+5.1V (IA) +12V (IB) –5V (IC) +5.1V (IA) +15V (IB) –15V (IC) +5.1V (IA) +12V (IB)
5V
3A 2A 0.35A 3A 1.5A 0.35A 3A 2A 6A
7A 3A 1.0A 7A 3A 1A 7A 3A 10A
4A 2A 0.5A 4A 1.5A 0.5A 4A 2A 8A
50mV 120mV 50mV 50mV 160mV 150mV 50mV 120mV 50mV
±3.0% NAL40-7607 (5) ±5.0% ±5.0% ±3.0% NAL40-7610 (5) +13% –0% ±5.0% ±3.0% NAL40-7629 (5) ±5.0% ±3.0% NAL40-7605
NAN40-7607 (5) NAN40-7610 (5) NAN40-7629 (5)
NAN40-7605
12V 3.3A
5A
4A
120mV
±3.0%
NAL40-7612
NAN40-7612
15V 2.6A
4A
3.3A
150mV
.