DatasheetsPDF.com

IM04GR Dataheets PDF



Part Number IM04GR
Manufacturers Tyco
Logo Tyco
Description IM Relay
Datasheet IM04GR DatasheetIM04GR Datasheet (PDF)

IM Relay AXICOM Telecom-, Signal and RF Relays 108-98001 • Sep. 07 Rev. G • ECOC: JM10 AXICOM Telecom-, Signal and RF Relays IM Relay 108-98001 Rev. G Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, Tyco Electronics does not guarantee that it is error-free, nor does Tyco Electronics make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. Tyco Electronic.

  IM04GR   IM04GR


Document
IM Relay AXICOM Telecom-, Signal and RF Relays 108-98001 • Sep. 07 Rev. G • ECOC: JM10 AXICOM Telecom-, Signal and RF Relays IM Relay 108-98001 Rev. G Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, Tyco Electronics does not guarantee that it is error-free, nor does Tyco Electronics make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. Tyco Electronics reserves the right to make any adjustments to the information contained herein at any time without notice. Tyco Electronics expressly disclaims all implied warranties (and all express warranties, except as otherwise stated in this datasheet) regarding the information contained herein, including but not limited to any implied warranties or merchantability or fitness for a particular purpose. It is recommended that you test any new or replacement product before incorporating into a system. The dimensions in this datasheet are for reference purpose only and are subject to change without notice. Specifications are subject to change without notice. UL 508 File No. E 111441 UL 60950 IEC/EN60950 IEC Ref. Cert. No. 3270 Index Dimensions Coil Operating Range Coil Data and Ordering Information Contact Data Insulation General Data Packing All specifications subject to change. Consult Tyco Electronics for latest specifications. 4 5 6 10 11 11 13 2 of 15 AXICOM Telecom-, Signal and RF Relays IM Relay Slim line AND low profile 2 pole telecom/signal relay, polarized Through Hole Types (THT), standard version with 5.08 mm, narrow version with 3.2 mm between the terminal rows or Surface Mount Type (SMT) Relay types: non-latching with 1 coil latching with 1 coil ROHS compliant (Directive 2002/95/EC) as per product date code 0438. Features • Telecom/signal relay (dry circuit, test access, ringing) • Slim line 10 x 6 mm, 0.39 x 0.24 inch • Low profile 5.65 mm, 0.222 inch • Minimum board-space 60 mm2 • Switching current 2 A / 5 A • 2 changeover contacts (2 form C / DPDT) • Bifurcated contacts, gold plated • High sensitivity results in low nominal power consumption 140 mW for non latching standard 100 mW for latching version and non latching high sensitive version • Ultra high sensitive type 50 mW for non latching • High surge capability (1.2/50 µs and 10/700 µs) meets Telcordia GR 1089, FCC Part 68 and ITU-T K20, 21, 45 1500 V between open contacts 2500 V between coil and contacts • High mechanical shock resistance up to 300 G functional, up to 500 G survival • Hermetically sealed (RT V) Typical applications • Communications equipment Linecard application – analog, ISDN, xDSL, PABX Voice over IP • Office and business equipment • Measurement and control equipment • Consumer electronics, Set top boxes, HiFi • Medical equipment Options • Surge capability 2500 V between open contacts 108-98001 Rev. G Insulation category Supplementary insulation according Working voltage Mains supply voltage Repetitive peak voltage Pollution degree Flammability classification Maximum operating temperature IEC / EN 60950 ≤ 300 Vrms ≤ 250 Vrms 2500 V Internal: 1 External: 2 V-0 85 °C All specifications subject to change. Consult Tyco Electronics for latest specifications. 3 of 15 AXICOM Telecom-, Signal and RF Relays IM Relay 108-98001 Rev. G Dimensions Dimensions in mm IM THT Standard mm inch L 10.00 ± 0.08 0.393 ± 0.003 W 6.00 ± 0.08 0.236 ± 0.003 H 5.65 – 0.20 0.222 – 0.008 T 3.2 0.125 T1 N/A N/A T2 5.08 ± 0.10 0.200 ± 0.004 D1 3.20 ± 0.15 0.126 ± 0.006 D2 2.20 ± 0.15 0.087 ± 0.006 Tw 0.40 0.015 S 0.30 ± 0.05 0.011 ± 0.002 IM THT Narrow mm inch 10.00 ± 0.08 0.393 ± 0.003 5.70 ± 0.30 0.224 ± 0.012 5.80 ± 0.08 0.230 ± 0.003 3.2 0.125 N/A N/A 3.20 ± 0.10 0.126 ± 0.004 3.20 ± 0.15 0.126 ± 0.006 2.20 ± 0.15 0.087 ± 0.006 0.4 0.015 0.30 ± 0.05 0.011 ± 0.002 THT Version Standard version Narrow version IM SMT Gull Wings mm inch 10.00 ± 0.08 0.393 ± 0.003 6.00 ± 0.08 0.236 ± 0.003 5.65 – 0.20 0.222 – 0.008 N/A N/A 7.50 ± 0.30 0.295 ± 0.011 5.08 ± 0.10 0.200 ± 0.004 3.20 ± 0.15 0.126 ± 0.006 2.20 ± 0.15 0.087 ± 0.006 0.4 0.015 N/A N/A SMT Version Gull Wings IM SMT J-Legs mm inch 10.00 ± 0.08 0.393 ± 0.003 6.00 ± 0.08 0.236 ± 0.003 5.65 – 0.02 0.222 – 0.008 N/A N/A 2.80 ± 0.20 0.110 ± 0.007 5.08 ± 0.10 0.200 ± 0.004 3.20 ± 0.15 0.126 ± 0.006 2.20 ± 0.15 0.087 ± 0.006 0.4 0.015 N/A N/A J-Legs Mounting hole layout View onto the component side of the PCB (top view) Standard version Narrow version Solder pad layout View onto the component side of the PCB (top view) Gull Wings J-Legs Ø min. 0.75 Ø min. 0.75 Terminal assignment Relay – top view Non-latching type not energized condition Latching type, 1 coil reset condition Relay Code All specifications subject to change. Consult Tyco Electron.


IM03GR IM04GR IM05GR


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)