Green-Mode PWM Controller
LD7752B
6/11/2013
Green-Mode PWM Controller with HV Start-Up Circuit and Soft Start time Adjustment
REV. 00
General Des...
Description
LD7752B
6/11/2013
Green-Mode PWM Controller with HV Start-Up Circuit and Soft Start time Adjustment
REV. 00
General Description
The LD7752B brings high performance, highly integrated functions, protections and EMI-improve solution. It’s an ideal solution for those cost-sensitive system, reducing component count and overall system cost.
The LD7752B features high voltage startup circuit, minimum loss and green-mode power-saving operation, leading-edge blanking of the current sensing and internal slope compensation. They also consist of more protections of OLP (Over Load Protection) and OVP (Over Voltage Protection) to prevent the circuit from damage under abnormal conditions.
Furthermore, the proprietary frequency swapping function can reduce the noise and help the power circuit designers to enhance EMI performance with fewer components and less developing time.
Features
High-Voltage Startup Circuit UVLO (Under Voltage Lockout) LEB (Leading-Edge Blanking) on CS Pin Internal Frequency swapping Internal Slope Compensation Internal OCP Compensation OVP (Over Voltage Protection) on Vcc Pin OLP (Over Load Protection) +250mA/-500mA Driving Capability Soft-Driving Soft Start Time and Grouping Frequency Adjustment
Applications
LCD Monitor/TV Power Switching AC/DC Adaptor and Battery Charger Open Frame Switching Power Supply
Typical Application
AC EMI input Filter
HV VCC
*CT OUT LD7752B CS GND COMP
photocoupler
Leadtrend Technology Corporation LD7752B-...