Logo Tyco
Description Magnetic Hydraulic Circuit Breakers
Datasheet W69-X2Q110-20 DatasheetW69-X2Q110-20 Datasheet (PDF)

W6/W9 series Magnetic Hydraulic Circuit Breakers Features • Designed for the international market. UL Recognized, CSA Certified, and VDE approved. • Ratings to 50 amps. • Heavy duty #10-32 stud connections. (W9) • Optional 10 amp auxiliary switch. • Optional snap-in mounting. (W6) • Several delay curve options. • Trip-free operation. Typical Resistance and Impedance Current (Amps) 0.2 1.0 2.0 5.0 10.0 20.0 30.0 40.0 50.0 DC Resistance (Ohms) 90 1.2 0.28 0.04 0.013 0.004 0.0027 0.002 0.0015 50/.

  W69-X2Q110-20   W69-X2Q110-20


Document
W6/W9 series Magnetic Hydraulic Circuit Breakers Features • Designed for the international market. UL Recognized, CSA Certified, and VDE approved. • Ratings to 50 amps. • Heavy duty #10-32 stud connections. (W9) • Optional 10 amp auxiliary switch. • Optional snap-in mounting. (W6) • Several delay curve options. • Trip-free operation. Typical Resistance and Impedance Current (Amps) 0.2 1.0 2.0 5.0 10.0 20.0 30.0 40.0 50.0 DC Resistance (Ohms) 90 1.2 0.28 0.04 0.013 0.004 0.0027 0.002 0.0015 50/60 Hz. Impedance (Ohms) 90 1.2 0.28 0.04 0.013 0.005 0.004 0.002 0.0015 400 Hz. Impedance (Ohms) 180 2.0 0.50 0.05 0.025 0.0065 0.004 0.003 0.0025 Tolerance: 0.1 - 4.99 ± 15%; 5 - 9.99 ± 20%; 10 - 15 ± 25%; 16 - 30 ± 50%. Agency Approvals Recognized as Supplementary Protector under UL 1077 . File E69543. CSA: Certified as a Supplementary Protector. File LR15734. VDE: Approved to VDE 0642/EN 60 934 (Circuit Breakers for Equipment) License No. 73782. UL: Mechanical/Environmental Data Operating Temperature: -40°C to +85°C. Humidity: Meets requirements of Mil-STD-202 method 103. Shock: Tested per Mil-STD-202, method 213, test condition C (100g @ 6 ms). Vibration: Tested per Mil-STD-202, method 201, 10-55 Hz., 0.06" (1.52mm) total excursion in 2 planes. Fungus And Moisture Resistance: Special moisture resistant finish applied to all ferrous parts. Plastic parts are made of inherently fungus resistant material. Marking: W6 units have ON and OFF molded on the rocker of rocker actuated units (rocker actuated VDE units have international “1” and “0”). W9 units have ON and OFF molded into the area at the base of the toggle. International “1” and “0” symbols are marked on the toggle for both W6 and W9. Mounting: Panel mounted units are mounted with two #6-32 screws from the front of the panel. Metric models for use with M3 x 0.5 screws are available. Units with snap-in mounting option snap through the front of the panel. To maintain published performance specifications, units should not be mounted more than 90° from their normal upright position. Weight: Approximately 2.5 ounces per pole. Electrical Data Auxiliary Switch: See Auxiliary Switch Ratings Table 2 for details. Calibration: Breakers will hold 100% of rated current. Breakers may trip between 101% and 124% of rated load (149% for 400 Hz. units and 134% for AC/DC units). Breakers must trip at 125% of rated load and above (150% for 400 Hz. units and 135% for AC/DC units). Dielectric Strength: 50/60 or 400 Hz., 1500V: DC, 1100V. Insulation Resistance: 100 Megohms at 500VDC. Endurance: 10,000 on/off cycles - 6000 at rated load, 4000 at no load. Units tested at six cycles per minute, 1 second on and 9 seconds off at 25°C ambient. Approvals and Ratings Table 1 W6 Series Maximum Voltage 65 277 277 277/480 250 250 250 UL/CSA (All Circuit Functions) Frequency (Hz) DC 50/60 50/60 50/60 400 400 400 Current Phase 1 1 3Ø-Wye 1 1 3Ø-Wye Interrupting Rating (Amps) 0.2 - 50 0.2 - 20 21 - 50 0.2 - 20 0.2 - 20 21 - 50 0.2 - 20 Capacity (Amps) 2,000 5,000 2,500 5,000 2,500 1,250 2,500 W6 Series Maximum Voltage 65 250 250 415/240 VDE (Circuit Function X) Frequency (Hz) DC 50/60 50/60 50/60 Current Phase 1 1 3Ø Interrupting Rating (Amps) 0.2-50 0.2-30 31-50 0.2-30 Capacity (Amps) 2,000 5,000 2,000 5,000 W9 Series Maximum Voltage 65 277 277/480 250 250 UL/CSA (All Circuit Functions) Frequency (Hz) DC 50/60 50/60 400 400 Current Phase 1 3Ø-Wye 1 3Ø-Wye Interrupting Rating (Amps) 0.2 - 50 0.2 - 50 0.2 - 20 0.2 - 50 0.2 - 50 Capacity (Amps) 2,000 5,000 5,000 2,500 2,500 W9 Series Maximum Voltage 65 250 250 415/240 VDE (Circuit Function X) Frequency (Hz) DC 50/60 50/60 50/60 Current Phase 1 1 3Ø Interrupting Rating (Amps) 0.2-50 0.2-30 31-50 0.2-30 Capacity (Amps) 2,000 5,000 2,000 5,000 Approvals and Ratings Table 2 UL/CSA Switch Number A Voltage 50/60 Hz. 125 Current (Amps) 10 Terminals WxTxL .093 x .020 x .250 (2.36 x .51 x 6.40) VDE Switch Number V1 V2 V3 Voltage 50/60 Hz. 250 250 250 Current (Amps) 10 5 0.1 Terminals WxTxL .110 x .020 x .280 (2.79 x .51 x 7 .11) Time vs. Current Trip Curves For W6 Series and W9 Series AC 50/60 Hz. DC & 50/60 Hz. 400 Hz. 10,000 1000 CURVE 0 NON-TIME DELAY TRIP TIMES OVERLOAD @ 50/60 Hz. & DC @ 400 Hz. 125% 150% 200% 400% 600% 800% 100 ms max. 55 ms max. 30 ms max. 15 ms max. 12 ms max. 12 ms max. May Trip 100 ms max. 30 ms max. 15 ms max. 12 ms max. 12 ms max. 10,000 1000 CURVE 2 AC VOLTAGE 50/60 Hz. OVERLOAD TRIP TIMES (SEC.) 125% 200% 400% 600% 800% 1000% 10 - 150 2.2 - 20 .2 - 2 .03 - .75 .007 - .15 .005 - .04 10,000 1000 CURVE 3 AC VOLTAGE 50/60 Hz. OVERLOAD TRIPTIMES (SEC.) 125% 200% 400% 600% 800% 1000% 1 - 15 .15 - 1.5 .03 - .25 .007 - .15 .003 - .08 .003 - .04 TIME IN SECONDS TIME IN SECONDS 100 10 1 .1 .01 100 10 1 .1 .01 TIME IN SECONDS 100 10 1 .1 .01 .001 0 100 200 300 400 500 600 700 800 900 1000 1 100 1200 125 150 LOAD CURRENT AS A PERCENT OF BREAKER RATING .001 0 100 200 300 400 500 600 700 800 900 1000 1 100 120.


W69-X2Q12-30 W69-X2Q110-20 W69-X2Q110-30


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)