Document
Aperio™ Hub AH20/AH30 Installation Instructions
Covers AAWL-260 3 May 2011
ASSA ABLOY, the global leader in door opening solutions
1
http://www.Datasheet4U.com
AH20/AH30 - Table of Contents
AH20/AH30 - FCC and Industry Canada Statements AH20/AH30 - Placement of Communication Hub AH20 (J100) - Connections AH20 (J103) - Connections AH20 - DIP Switch Configuration Table AH30 (J100) - Connections AH30 - DIP Switch Configuration Table AH30 - RS485 Bus Connection AH30 - RS485 Addressing AH20/AH30 - Communication Hub LED Indication AH20/AH30 - Technical Data
ETL marking
Recognized component
3 4 5-6 7 8 9 10 11 12-13 14 15
4002570
Conforms to ANSI/UL standard 294, ANSI/UL 60950-1 Certified to CAN/CSA standard C22.2 No. 60950-1 2
AH20/AH30 - FCC and Industry Canada Statements
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2)This device must accept any interference received, including interference that may cause undesired operation.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence.L’exploitation est autorisée aux deux conditions suivantes: 1. l’appareil ne doit pas produire de brouillage, et 2. l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
The term “IC:” before the equipment certification number only signifies that the Industry Canada technical specifications were met.
Le terme “IC” devant le numéro de certification signifie seulement que les spécifications techniques Industrie Canada ont été respectées.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
IEEE 802.15.4 operation of this product in U.S.A. and Canada is limited to channels 11-25 by Aperio Programming Application. Outside of U.S.A. and Canada another version of the Aperio programming application allow use of channels 11-26.
3
AH20/AH30 - Placement of Communication Hub
< 25 m / ~ 82 ft
AH20 (Wiegand Hub) - Placement of the Hub, 1 door
Note: AH20 can be installed with an Aperio bottom cover or Americas adaptor plate.
< 25 m / ~ 82 ft
AH30 (RS485 Hub) - Placement of the Hub, 1-8 doors
Note: Note: AH20/AH30 must be installed into a junction box ex European 2-Gang, Aperio bottom cover or with Americas adaptor plate to junction box. AH20/AH30 shall only be installed with qualified and trained personal. Indoor installation only! 4
AH20 (J100) - Connections
AH20 Connectors (J100) Note: The installation shall comply with national wiring regulations. 5
AH20 (J100) - Connections
Communication Hub hardware version AH20 has four Wiegand signals plus power supply. The purpose and connection of these signals are described in the table below.
Hub Conne tor
cc
Des ription
DATA 1
Wiegand Data 1 signal. Output from Communication Hub. Used to transmit credentials.
DATA 0
Wiegand Data 0 signal. Output from Communication Hub. Used to transmit credentials.
RED GREEN
Wiegand RED LED signal. Input to Communication Hub. Used for access decision. Leave unconnected if DIP switch 1 is selected “OFF”. Signal is active low. Wiegand Green LED signal. Input to communication Hub. Used for access decision. Signal is active low. See DIP 1 for alternate instructions.
GND
GND = Signal ground. Should be connected to EAC system GND and power supply GND.
8-24 VDC
Power supply input, 8-24 V DC. The power supply shall be a Limited Power Source (LPS) according to EN 60950-1. The power supply shall be 3A over current protected. Wire requirements 16-22 AWG.
AH20 Connectors (J100)
6
AH20 (J103) - Connections
AH20 Connectors (J103)
elays
Des ription
ccR cR
R.