Document
1
5 Port Pilot Operated Solenoid Valve Rubber Seal
Series VF1000/3000/5000
VK
Large flow capacity
Yet compact size.
VZ VF VFR
Low power consumption
1.8 W (DC)
VP4 VZS
Exhausting equipment for pilot valve not required.
Common exhaust port for main and pilot valve (VF1000/3000)
VFS VS4 VQ7 EVS VFN
www.DataSheet.net/
VF5000
C: 12 dm3/(s·bar)
{4/2 Ǟ 5/3 (A/B Ǟ EA/EB)}
32 mm width
VF3000
C: 3.1 dm3/(s·bar) C: 0.53 dm3/(s·bar) 26.4 mm width
{4/2 Ǟ 5/3 (A/B Ǟ EA/EB)}
VF1000
{4/2 Ǟ 5/3 (A/B Ǟ EA/EB)}
26.4 mm width
3-4-1
Datasheet pdf - http://www.DataSheet4U.co.kr/
2
Series
VF1000/3000/5000
Many combinations available to fit your needs.
Series Variations/Port Size
VF1000
VF1000
18
2 position single
2 position double
VF3000
VF3000
18 14 38
2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center
VF5000
VF5000
14 38 12
2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center
Piping
Body ported VF1000 VF3000 VF5000 Base mounted VF3000 VF5000
Pilot Exhaust
Pilot valve individual exhaust (Standard) Pilot exhaust port
Common exhaust type for main and pilot valve (VF1000, VF3000)
www.DataSheet.net/
Manual Override
Push type Locking type B (Slotted) Locking type C (Manual)
Manual override Manual override Manual override
(Illustration: VF3000)
(With sub-plate)
Rated Voltage Surge Voltage AC/ Suppressor/Indicator Light
100 V, 200 V, 12 V∗, With surge voltage 24 V∗, 48 V∗, suppressor (S) ∗ ∗ 110 V , 220 V (Grommet type) 240 V∗ With light/surge voltage suppressor (Z) (Grommet terminal) (Conduit terminal) (DIN terminal) L plug connector M plug connector
Light Surge voltage suppressor
Electrical Entry
Grommet (G) Grommet terminal (E) Conduit terminal (T) DIN terminal (D), (Y) L plug connector (L)
Note)
DC/ 24 V, 6 V∗, 12 V∗ 48 V∗, 100 V∗ 110 V∗ (∗ Option)
M plug connector (M)
Note)
Note) VF1000/VF3000 only.
Manifold Variations
VF1000
VF3000
VF5000
VV5F1-30
Manifold type B mount
VV5F3-30
VV5F3-60
VV5F5-20
A, B port EXH type Manifold type CYL port EXH type Valve Common, Individual B mount Valve, Base Common, Individual
EXH type Manifold type CYL port EXH type Manifold type A, B port S mount Valve Common, Individual B mount Valve, Base Common
3-4-2
Datasheet pdf - http://www.DataSheet4U.co.kr/
3
Series
Precautions
VF1000/3000/5000
Be sure to read before handling. For Safety Instructions and Solenoid Valve Precautions, refer to page 3-13-2.
Light/Surge Voltage Suppressor Common Exhaust Type for Main and Pilot
Exhaust air from pilot valve will flow to main valve exhaust port. Exhaust air from main valve will not flow to pilot valve side due to a check valve. Purpose • Not to exhaust mist from PE (Pilot Exhaust) port to protect the surrounding environment • To lower the exhaust noise from PE port when switching valve. • To prevent silencer mounted to PE port from getting plugged in dusty environments..