SAW Filter
®
SF2027B 199.0 MHz SAW Filter
+18 dBm +10 dBm 10V
• • •
GSM BTS Receiver IF Applications Small Size Hermetic 13.3 X ...
Description
®
SF2027B 199.0 MHz SAW Filter
+18 dBm +10 dBm 10V
GSM BTS Receiver IF Applications Small Size Hermetic 13.3 X 6.5 mm Surface Mount Case
Input power Level short test standard operation, max Max DC Voltage between any 2 terminals Input: possible for balanced and unbalanced operation (TBD) Output: Balanced External matching to 50 or 200 ohms
SMP-53-S
Electrical Characteristics
Characteristic Nominal Frequency Insertion Loss Group Delay Ripple, peak - peak Amplitude Ripple, peak - peak Relative attenuation fn - 300 kHz, fn - 500 kHz, fn - 600 kHz, (including matching to 200 ohms) (198.9 .. 199.1 MHz) (198.9 .. 199.1 MHz) fn +300 kHz fn +500 kHz fn +600 kHz
www.DataSheet.net/
Sym fN IL
Notes 1
Min
Typ 199.0 < 7.0 < 700 < 1.0 < 0.7 > 10 > 27 > 36 > 45
Max
Units MHz dB ns dB dB dB dB dB
fn - 100 kHz .. fn +100 kHz (passband)
fn +700 kHz Case Style Lid Symbolization (Y=year, WW=week, S=shift) See note 4
SMP-53-S 13.3 X 6.5 mm Nominal Footprint RFM SF2027B YWWS
Notes:
1. Unless noted otherwise, all specifications apply over the operating temperature range with filter soldered to the specified demonstration board with impedance matching to 50 Ω and measured with 50 Ω network analyzer. A dB offset exists for RFM because of the loss introduced by using transformers on the Input and Output. Rejection is measured as attenuation below the minimum IL point in the passband. Rejection in final user application is dependent on PCB layout and external imped...