DatasheetsPDF.com

G3PC-220B-VD Dataheets PDF



Part Number G3PC-220B-VD
Manufacturers Omron
Logo Omron
Description SSR
Datasheet G3PC-220B-VD DatasheetG3PC-220B-VD Datasheet (PDF)

SSR with Failure Detection Function G3PC Detects failures in SSRs used for heater temperature control and simultaneously outputs alarm signals. This product supports the safe design of heater control systems, and contributes to maintenance improvements by the user. • Main detection items: SSR short-circuits and SSR open-circuits • Alarm output possible to NPN/PNP-input devices. • The failure-detection function is built-in and power is supplied from the main circuit power supply making wiring si.

  G3PC-220B-VD   G3PC-220B-VD


Document
SSR with Failure Detection Function G3PC Detects failures in SSRs used for heater temperature control and simultaneously outputs alarm signals. This product supports the safe design of heater control systems, and contributes to maintenance improvements by the user. • Main detection items: SSR short-circuits and SSR open-circuits • Alarm output possible to NPN/PNP-input devices. • The failure-detection function is built-in and power is supplied from the main circuit power supply making wiring simple. • Slim design (width: 22.5 mm) incorporating radiator. • In addition to screw mounting, DIN track mounting is also possible. • Conforms to international standards (IEC, UL, and CSA). Ordering Information I List of Models Insulation method Phototriac coupler Yes Zero-cross function Indicators Yes (See page 75) www.DataSheet.co.kr Applicable output load 20 A, 100 to 240 VAC (resistive load: AC, Class1) Model number G3PC-220B-VD I Accessories (Order Separately) Name Mounting Track Dimensions 50 cm (l) × 7.3 mm (t) 1 m (l) × 7.3 mm (t) 1 m (l) × 16 mm (t) PFP-50N PFP-100N PFP-100N2 Model number Specifications Detection Power Supply Rated power supply voltage Operating voltage range Current consumption 100 to 240 VAC (50/60 Hz) 75 to 264 VAC (50/60 Hz) 15 mA AC max. (at 200 VAC) Main Circuit Rated load voltage Operating voltage range Rated carry current Minimum load current Inrush current resistance (peak value) Permissible (I t) Applicable load (with Class-1 AC resistive load) 2 100 to 240 VAC (50/60 Hz) 75 to 264 VDC (50/60 Hz) 20 A (Ta = 40) 0.1 A 220 A (60 Hz, 1 cycle) 260 A2S 4 kW (at 200 VAC) Operating Circuit Input method Rated input voltage Operating input voltage range Must-operate voltage Reset voltage Input current Voltage input 12 to 24 VDC 9.6 to 30 VDC 9.6 VDC max. 1 VDC min. 7 mA DC max. (at rated input voltage) Alarm Output Output OFF collector voltage Maximum carry current Output form 30 VDC max. 0.1 A Independent NPN open collector SSR with Failure Detection Function G3PC J-71 Datasheet pdf - http://www.DataSheet4U.net/ SSR I Ratings (At an Ambient Temperature of 25°C) I Characteristics Operate time Release time Main circuit Alarm output Output ON voltage drop OFF leakage current Output ON voltage drop OFF leakage current Insulation resistance Dielectric strength Vibration resistance Shock resistance Ambient temperature Ambient operating humidity Weight Approved standards EMC 1/2 of load power source cycle + 1 ms max. 1/2 of load power source cycle + 1 ms max. 1.6 V rms max. 10 mA max. (at 200 VAC) 1.5 V max. 0.1 mA max. 100 MΩ min. (at 500 VDC) 2,500 VAC, 50/60 Hz for 1 min Destruction: 10 to 55 to10 Hz, 0.35-mm single amplitude Destruction: 294 m/s2 Operating: -20 to 60°C (with no icing or condensation) Storage: -30 to 70°C (with no icing or condensation) 45% to 85% Approx. 300 g UL508, CSA22.2 No. 14, EN60947-4-3 (IEC947-4-3) approved by VDE Emission Immunity Immunity Immunity Immunity Immunity Immunity ESD Electromagnetic EFT Surge transient RF disturbance Dips EN55011 Group 1 Class B IEC947-4-3, EN61000-4-2 4 kV contact discharge 8 kV air discharge IEC947-4-3, EN61000-4-3 10 V/m (80 MHz to 1 GHz) IEC947-4-3, EN61000-4-4 2 kV AC power-signal line IEC947-4-3, EN61000-4-5 2 kV IEC947-4-3, EN61000-4-6 10 V (0.15 to 80 MHz) IEC947-4-3, EN61000-4-11 Engineering Data Input Voltage vs. Input Current Input Voltage vs. Input Impedance Input impedance (kΩ) Input current (mA) 10 Ta = +25°C Load Current vs. Ambient Temperature www.DataSheet.co.kr Inrush Current Resistivity (Non-repetitive Input) The figure will be less than 1/2 for repetitive input. 8 Load current (A) 25 Inrush current (A. Peak) 250 20 200 Input impedance 6 15 150 4 Input current 2 10 100 5 50 0 10 20 30 40 Input voltage (V) -20 0 0 20 40 60 80 100 Ambient temperature (˚C) 0 10 30 50 100 300 500 1,000 3,000 5,000 Energized time (ms) J-72 SSR with Failure Detection Function G3PC Datasheet pdf - http://www.DataSheet4U.net/ Operation I Failure Detection Function Conditions for SSR Failure Detection Failure mode (See note 1.) SSR short-circuit SSR open-circuit Operating input (between terminals A1 and A2) OFF ON Detection time Alarm display (See note 3.) 0.5 s max. (See note 2.) Red SSR half-wave short-circuit OFF SSR half-wave open-circuit ON Note: 1. The contents of each of the above failure modes is as follows: SSR short-circuit: SSR output circuit remains in the ON state. SSR half-wave short-circuit: SSR output circuit remains in the ON state in one direction. SSR open-circuit: SSR output circuit remains in the OFF state. SSR half-wave open-circuit: SSR output circuit remains in the OFF state in one direction. In addition to the failure modes listed above, detection of circuit disconnections for the load circuit is also possible. (As a rough guide, circuit disconnection will be detected if the load impedance is greater than or equal to 1 MΩ.) 2. The same power supply is used for both the de.


G3PC G3PC-220B-VD HA5142


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)