2 Watts 2 :1 Wide Input Range DC/DC Converters
Single Outputs
Key Features
MCW1000 Series
y y y y y y y y y
High Efficiency up to 80% 2:1 Input Range I/O Isolation 1000VDC Industry Standard Pinout SMT Technology Short Circuit Protection MTBF > 1,000,000 Hours External ON/OFF-Control Low Ripple and Noise
MCW1000-Series power modules are low-profile dc-dc converters that operate over input voltage ranges of 4.5-9VDC, 9-18VDC, 18-36VDC and 36-75VDC and provide precisely regulated output voltages of 3.3V, 5V, 12V. The -40] to +65] operating temperature range makes it ideal for data communication equipments, mobile battery driven equipments, distributed power systems, telecommunication equipments, mixed analog/digital subsystems, process/machine control equipments, computer peripheral systems and industrial robot systems. The modules have a maximum power rating of 2W and a typical full-load efficiency of 80%, continuous short circuit, 60mV output ripple, built-in filtering for both input and output minimizes the need for external filtering.
Low Noise
I/O Isolation
Remote on/off
$
Low Cost Low Profile
2:1
Wide Range
Block Diagram
+Vin
+Vo
-Vo
-Vin On/Off PFM Isolation Ref.Amp
Datasheet pdf - http://www.DataSheet4U.net/
www.DataSheet.co.kr
MCW1000 Series
Model Selection Guide
Model Number Input Voltage VDC MCW1011 MCW1012 MCW1013 MCW1021 MCW1022 MCW1023 MCW1031 MCW1032 MCW1033 MCW1041 MCW1042 MCW1043 5 ( 4.5 ~ 9 ) 12 ( 9 ~ 18 ) 24 ( 18 ~ 36 ) 48 ( 36 ~ 75 ) Output Voltage VDC 3.3 5 12 3.3 5 12 3.3 5 12 3.3 5 12 Output Current Max. mA 500 400 167 500 400 167 500 400 167 500 400 167 Min. mA 125 100 42 125 100 42 125 100 42 125 100 42 Input Current @Max. Load mA (Typ.) 471 548 534 184 217 209 96 109 103 49 57 53 @No Load mA (Typ.) 40 Efficiency @Max. Load % (Typ.) 70 73 75 73 77 80 72 77 81 71 73 79
20
10
8
Absolute Maximum Ratings
Parameter 5VDC Input Models 12VDC Input Models Input Surge Voltage ( 1000 mS ) 24VDC Input Models 48VDC Input Models Lead Temperature (1.5mm from case for 10 Sec.) Internal Power Dissipation Min. -0.7 -0.7 -0.7 -0.7 ----Max. 15 25 50 100 260 1,800 Unit VDC VDC VDC VDC ] mW
Note :
1. Specifications typical at Ta=+25], resistive load, nominal input voltage, rated output current unless otherwise noted. 2. Transient recovery time is measured to within 1% error band for a step change in output load of 50% to 100%. 3. Ripple & Noise measurement bandwidth is 0-20 MHz. 4. These power converters require a minimum output loading to maintain specified regulation. 5. Operation under no-load conditions will not damage these devices; however they may not meet all listed specifications. Min. Max. -40 +65 -40 +90 -55 +105 --95 Free-Air Convection Unit ] ] ] % 6. All DC/DC converters should be externally fused at the front end for protection. 7. Other input and output voltage may be available, please contact factory. 8. Specifications subject to change without notice.
Exceeding these values can damage the module. These are not continuous operating ratings.
Environmental Specifications
Parameter Operating Temperature Operating Temperature Storage Temperature Humidity Cooling Conditions Ambient Case
Datasheet pdf - http://www.DataSheet4U.net/
www.DataSheet.co.kr
MCW1000 Series
Input Specifications
Parameter Start Voltage Model 5V Input Models 12V Input Models 24V Input Models 48V Input Models Under Voltage Shortdown 5V Input Models 12V Input Models 24V Input Models 48V Input Models Reverse Polarity Input Current Short Circuit Input Power Input Filter All Models Min. 3.5 4.5 8 16 ------------Typ. 4 7 12 24 3.5 6.5 11 22 ----Max. 4.5 9 18 36 4 8.5 17 34 1 1500 A mW VDC Unit
Capacitor type
Output Specifications
Parameter Output Voltage Accuracy Line Regulation Load Regulation Ripple & Noise (20MHz) Ripple & Noise (20MHz) Ripple & Noise (20MHz) Over Power Protection Transient Recovery Time Transient Response Deviation Temperature Coefficient Output Short Circuit 25% Load Step Change Over Line,Load & Temp Vin=Min. to Max. Io=25% to 100% Conditions Min. ------------120 ------Continuous Typ. {1 {0.3 {0.5 30 ------100 {3 {0.01 Max. {2 {0.5 {0.75 50 75 15 --300 {5 {0.02 Unit % % % mV P-P mV P-P mV rms. % uS % %/]
General Specifications
Parameter Isolation Voltage Isolation Test Voltage Isolation Resistance Isolation Capacitance Switching Frequency MTBF MIL-HDBK-217F @ 25], Ground Benign Conditions 60 Seconds Flash Tested for 1 Second 500VDC 100KHz,1V Min. 1000 1100 1000 --100 1000 Typ. ------65 300 --Max. ------120 650 --Unit VDC VDC M[ pF KHz K Hours
Remote On/Off Control
Parameter Supply On Supply Off Device Standby Input Current Control Input Current ( on ) Control Input Current ( off ) Control Common Conditions Min. Typ. Max. 15 0.2 -0.4 1 Unit VDC mA mA mA under 1VDC or open circuit 2.7 --------0.1 -----
Referenced to Negative Input
Datasheet pdf - http://www.DataSheet4U.net/
www.DataSheet.co.kr
MCW1000 Series
Capacitive Load
Models by Vou.