DatasheetsPDF.com

ADC313 Dataheets PDF



Part Number ADC313
Manufacturers MPS Industries
Logo MPS Industries
Description Single & Dual Output DC/DC Converters
Datasheet ADC313 DatasheetADC313 Datasheet (PDF)

www.DataSheet.co.kr ADC300 SERIES 2W, Miniature SIP, Single & Dual Output DC/DC Converters Selection Guide Model Number ADC301 ADC302 ADC303 ADC304 ADC305 ADC306 ADC307 ADC311 ADC312 ADC313 ADC314 ADC315 ADC316 ADC317 ADC321 ADC322 ADC323 ADC324 ADC325 ADC326 ADC327 Input Voltage VDC Output Voltage VDC 3.3 5 12 15 ±5 ±12 ±15 3.3 5 12 15 ±5 ±12 ±15 3.3 5 12 15 ±5 ±12 ±15 Output Current mA 500 400 165 133 ±200 ±83 ±66 500 400 165 133 ±200 ±83 ±66 500 400 165 133 ±200 ±83 ±66 Efficiency % Typ. 73 .

  ADC313   ADC313



Document
www.DataSheet.co.kr ADC300 SERIES 2W, Miniature SIP, Single & Dual Output DC/DC Converters Selection Guide Model Number ADC301 ADC302 ADC303 ADC304 ADC305 ADC306 ADC307 ADC311 ADC312 ADC313 ADC314 ADC315 ADC316 ADC317 ADC321 ADC322 ADC323 ADC324 ADC325 ADC326 ADC327 Input Voltage VDC Output Voltage VDC 3.3 5 12 15 ±5 ±12 ±15 3.3 5 12 15 ±5 ±12 ±15 3.3 5 12 15 ±5 ±12 ±15 Output Current mA 500 400 165 133 ±200 ±83 ±66 500 400 165 133 ±200 ±83 ±66 500 400 165 133 ±200 ±83 ±66 Efficiency % Typ. 73 76 80 80 77 79 79 74 78 82 83 79 82 82 74 77 81 82 79 81 82 Load Regulation % Max. 11 11 7 7 10 7 7 8 8 5 5 8 5 5 8 8 5 5 8 5 5 5 (4.5 – 5.5) Key Features • • • • • • • • • • Efficiency up to 83% 1000VDC Isolation MTBF > 2,000,000 Hours Low Cost Input 5, 12 and 24VDC Output 3.3, 5, 12, 15, ±5, ±12 and ±15VDC Temperature Performance -40°C to +85°C UL 94V-0 Package Material Internal SMD Construction Industry Standard Pinout 12 (10.8 – 13.2) 24 (21.6 – 26.4) MPS Industries ADC300 DC/DC's are specially designed to provide higher power to 2W in a miniature SIP package. The series consists of 21 models with input voltages of 5V, 12V and 24VDC which offers standard output voltages of 3.3V, 5V, 12V, 15V, ±5V, ±12V and ±15VDC for a wide choice. The ADC300 series is an excellent selection for a variety of applications including distributed power systems, mixed analog/digital subsystems, portable test equipments, local power networks and battery backed systems. Mechanical Dimensions 19.5 [0.77] Pin Connections Pin Singles Duals 0.5 [0.02] 10.2 [0.40] 1 2 4 5 6 +Vin -Vin -Vout No Pin +Vout +Vin -Vin -Vout Common +Vout Case Size – 19.5x7.6x10.2mm (0.77x0.30x0.40inch) 3.2 [0.13] 2.3 [0.09] 2.54 [0.100] Case Material – Non-Conductive Black Plastic Weight – 2.7g (0.10Oz) 18.5 [0.73] 1 2 4 5 6 7.6 [0.30] 0.25 [0.010] 0.50 [0.020] 1.3 [0.05] Tolerance Millimeters X.X±0.25 X.XX±0.13 ±0.05 Inches X.XX±0.01 X.XXX±0.005 ±0.002 Pin 2463 208th Street, Ste. 205 Torrance, CA 90501 Tel: (310) 533-1455 Fax: (310) 533-1853 http://www.mpsind.com E-mail: [email protected] Datasheet pdf - http://www.DataSheet4U.net/ www.DataSheet.co.kr ADC300 SERIES 2W, Miniature SIP, Single & Dual Output DC/DC Converters Absolute Maximum Ratings Parameter 5VDC Input Models Input Surge Voltage 12VDC Input Models (1000mS) 24VDC Input Models Lead Temperature (1.5mm from case for 10sec.) Internal Power Dissipation General Characteristics Min. -0.7 -0.7 -0.7 ----- Max. Units 9 18 30 260 650 VDC VDC VDC °C mW Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency MTBF Conditions 60 Seconds 500VDC 100kHz, 1V Min. 1000 1000 --50 Typ. ----80 80 Max. ----120 100 Units VDC MΩ pF kHz Exceeding the unit absolute maximum ratings could cause damage. These are not continuous operating ratings. MIL-HDBK-217F @25°C Ground Benign 2 --- --- MHrs Environmental Characteristics Parameter Operating Temperature Operating Temperature Storage Temperature Humidity Cooling Output Characteristics Max. Units 85 90 125 °C °C °C % Parameter Line Regulation Load Regulation Ripple & Noise Short Circuit Conditions For Vin Change of 1% Io = 20% to 100% 20MHz BW Min. --Typ. ±1.2 Max. ±1.5 Units % % mV P-P Conditions Ambient Case Min. -40 -40 -40 See Selection Guide --100 150 --95 Free-Air Convection 0.5 Second Max. Maximum Capacitive Load Models by Output Voltage (Each Output on Duals) Singles 470 Duals 390 Units uF Derating Curve 100 80 Output Power (%) 100LFM 200LFM 400LFM Notes: 1. Specifications typical at Ta=+25°C, resistive load, nominal input voltage, rated output current unless otherwise noted. 2. These power converters require a minimum output load to maintain specified regulation. 3. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed. 4. All DC/DC converters should be externally fused at the front end for protection. 5. Other input and output voltage may be available, please contact factory. 6. All specifications subject to change without notice. 7. For detailed data sheet, please contact us. 60 Natural convection 40 20 0 -40 ¡ã 50 60 70 80 ] 90 100 110 Ambient Temperature 2463 208th Street, Ste. 205 Torrance, CA 90501 Tel: (310) 533-1455 Fax: (310) 533-1853 http://www.mpsind.com E-mail: [email protected] Datasheet pdf - http://www.DataSheet4U.net/ .


ADC312 ADC313 ADC314


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)