Characteristics
Remark: Reference level for the relative attenuation arel of the TFS 125K is the maximum attenuation in the pass band. The maximum attenuation in the pass band is defined as the insertion loss a e. The nominal frequency fN is fixed at 125 MHz without tolerance or limit. The values of relative attenuation a rel are guaranteed in the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
Insertion loss (Reference level) Nominal frequency 1 dB band width Pass band ripple within Relative attenuation fN fN 14 fN 28 fN + 14 fN + 23 fN + 33 VSWR fN - 150 MHz... fN MHz... fN MHz... fN + MHz... fN + MHz... fN + kHz ... fN + fN
BW ae
typ. value
1,88 dB
tolerance / limit
2,5 1,0 dB
2,80 0,10 MHz dB max.
125 300
MHz kHz
100KHz
arel
0,20 dB
150 kHz 28 124 23 33 325 MHz MHz MHz MHz MHz
50 65 40 55 42 1.3:1 dB dB dB dB dB
max. min. min. min. min. min. max
1 5 12 30 44 38 2:1
dB dB dB dB dB dB
150 kHz
GD*)
Absolute group delay fN 150 kHz ... fN +
150 kHz
GDR *)
245
ns
max. 300
ns
Group delay ripple fN 150 kHz ... fN +
150 kHz **)
15
ns
max. 100
ns
Intermodulation IP3 Input power level
54
TCf ***)
dB ppm/K
min. max
45 10 -
dB dBm
Temperature coefficient of...