Filter Specification
TFS 125 B
1/5
Measurement condition
Ambient t...
Description
tfs125B.doc
Version 1.0
06.03.01
VI TELEFILTER
Filter Specification
TFS 125 B
1/5
Measurement condition
Ambient temperature: Input power level: Terminating impedances: 23 0 50 °C dBm Ω
Characteristics
Remark: Reference level for the relative attenuation arel of the TFS 125 B is the minimum attenuation in the pass band. The minimum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 125 MHz without tolerance or limit. The values of relative attenuation arel are guaranteed in the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
typ. value
tolerance / limit
______________________________________________________________________________________________________ Insertion loss 1,5...... 3,5 dB ae (Reference level) ______________________________________________________________________________________________________ Nominal frequency 125,0 MHz fN ______________________________________________________________________________________________________ 1 dB bandwidth min. 300,0 kHz BW ______________________________________________________________________________________________________ Relative attenuation arel fN ..... fN ± 150 KHz max. 1,0 dB MHz min. 12,0 dB fN –124,0 MHz ... fN - 28 MHz min. 5,0 dB fN – 28,0 MHz ... fN - 14 min. 30,0 dB fN + 13,5 MHz ... fN +14,5 MHz min. 15,0 dB fN + 14,5 MHz ... fN +28,0 MHz MHz .....