TCXO
C2260
Typical Applications
PCS Base Stations Land Mobile Radio Cellular Telephony Radio in the Local Loop
TCXO
Feature...
Description
C2260
Typical Applications
PCS Base Stations Land Mobile Radio Cellular Telephony Radio in the Local Loop
TCXO
Features
EFC Standard Low Profile Small Size 100 % RoHS compliant
Frequency range Standard frequencies Frequency stabilities1
Parameter vs. operating temperature range (Referenced to +25°C)
www.DataSheet4U.com Parameter Initial tolerance vs. supply voltage change vs. load change vs aging /1. Year
6.4 MHz – 52 MHz 10; 12.8; 19.44; 20MHz, 20.48MHz
Operating temp Ordering Code5 range -20 … +70°C D256 -20 … +70°C D106 B106 0 … +50°C 0 … +50°C B507 Condition at time of shipment, nominal EFC VS ± 5% Load ± 10%
Min -2.5 -1.0 -1.0 -0.5 Min - 2.5 - 0.5 - 0.2 - 1.0
Typ
Max. +2.5 +1.0 +1.0 +0.5 Max. +2.5 +0.5 +0.2 +1.0
Units ppm ppm ppm ppm Units ppm ppm ppm ppm
Typ
Frequency stabilities1 [ Stratum 3 TCXO] < 32MHz
Parameter vs. operating temperature range (Referenced to +25°C) Min -0.8 -0.28 -0.28 -0.80 -0.28 -0.28 Min - 1.0 - 0.2 - 0.1 - 2.5 -4.6 Typ Typ Max. +0.8 +0.28 +0.28 +0.80 +0.28 -0.28 Max. +1.0 +0.2 +0.1 +2.5 -4.6 Units ppm ppm ppm ppm ppm ppm Units ppm ppm ppm ppm ppm Operating temp range -20 … +70°C 0 … +50°C -20 … +70°C -40 … +85°C -30 … +85°C -40 … +85°C Ordering Code5 D807 B287* D287* F807 G287 F287
Parameter Initial tolerance vs. supply voltage change vs. load change vs aging /15 Years overall tolerance
Condition at time of shipment, nominal EFC VS ± 5% Load ± 10%
Note * Stratum 3 per GR-1244-CORE: <±4.6 ppm for all causes and 20 years aging,Holdove...