Datasheet SIL855160 DatasheetSIL855160 Datasheet (PDF)

celpac® AC Semiconductor Contactor pitch 22,5mm compact size and DIN rail mounting. t Ready to use Single-Phase Relay: " Install it & Forget it!" 12-480VAC 50A back to back thyristors on output TMS2 technology - I2t value > 1500A2s. t This zero cross model switch ON in case of overvoltage: Autoprotection voltage for AC-51 loads only. t Large control range : 3 -32VDC with an input current < 10 mA on all the range. Green LED visualization on the input. www.DataSheet4U.com S/CLP/SIL855160/B/21/04/.

  SIL855160   SIL855160


Document
celpac® AC Semiconductor Contactor pitch 22,5mm compact size and DIN rail mounting. t Ready to use Single-Phase Relay: " Install it & Forget it!" 12-480VAC 50A back to back thyristors on output TMS2 technology - I2t value > 1500A2s. t This zero cross model switch ON in case of overvoltage: Autoprotection voltage for AC-51 loads only. t Large control range : 3 -32VDC with an input current < 10 mA on all the range. Green LED visualization on the input. www.DataSheet4U.com S/CLP/SIL855160/B/21/04/2004 page 1 / 4GB SIL855160 Output : 12-480VAC 32A(*) Input : 3 -32VDC / I<10mA t IP20 housing t Low leakage current (<1mA) and low zero cross voltage ( <10V) t Mounting and dismounting on DIN rail without any tool or directly mountable on panel. t Designed in conformity with EN60947-4-3 (IEC947-4-3) and EN60950 -UL-cUL (*) see conditions (thermal curve page 3) 22A Dimensions : 400VAC 50hz Protection L1 SSR Typical application: 9kW resistor (AC-51 load) on 400 VAC LOAD T1 A2 A1 - + Control Proud to serve you All technical caracteristics are subject to change without previous notice. Caractéristiques sujettes à modifications sans préavis. r celduc e l a i s celpac® Control characteristics (at 25°C) Paramètre / Parameter Control voltage Control current (@ Uc ) Release voltage Input LED Reverse voltage Clamping voltage Input immunity : EN61000-4-4 Input immunity : EN61000-4-5 Symbol Uc Ic Uc off Urv Uclamp Min 3 <10 1 DC Nom Max 5-12-24 32 <10 <10 green 32 42 2kV 2KV Unit V mA V V V S/CLP/SIL855160/B/21/04/2004 page 2 / 4GB Input : Ic = f( Uc) 12 10 8 Ic ( mA) 6 4 2 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 Uc ( VDC) Output characteristics (at 20°C) Parameter Load voltage Operating range Peak voltage www.DataSheet4U.com Clamping voltage : switch ON voltage in case of overvoltage Zero cross level Latching voltage AC-51 nominal current : permanent AC-53 nominal current Non repetitive overload current On state voltage drop (typical value) Dynamic resistance (typical value) Output Power dissipation (typical value) Thermal resistance between junction to air Off state leakage current Minimum load current Turn on time Turn off time Operating frequency range Off state dv/dt Maximum di/dt non repetitive I2t (<10ms) Conducted immunity level Conducted immunity level Short circuit protection General characteristics (at 20°C) Input to output insulation Output to case insulation Insulation resistance Rated impulse voltage Protection level / CEI529 Pollution degree Vibration resistance 10 -55 Hz according to CEI68 : Shocks resistance according to CEI68 ( on DIN rail / with screws) Ambient temperature (with no icing or condensation) Storage temperature (with no icing or condensation) Ambient humidity Weight Conformity Conformity Conditions on the thyristors typical value Ie nom ( see Fig. 2 page 3 ) tp=10ms (Fig. 3) @ 25°C Symbol Ue Uemin-max Up Uclamp Usync Ua Ie AC-51 Ie AC-53 Itsm Vt rt Pd Rthj/a Ilk Iemin ton max toff max f dv/dt di/dt I2t Typ. 400 12-480 1200 950/1000 10 8 32 12 550 0,9 8 0,81xIe+0,08xIe2 Unit V rms V rms V V V V A rms A rms A V mΩ W @Ue, 50Hz Uc nom DC ,f=50Hz Uc nom DC ,f=50Hz IEC 1000-4-4 (burst) IEC 1000-4-5(schocks) FERRAZ Ui Ui Ri Uimp double amplitude HR 3,3 (2,5) K/W <1 mA 5 mA 10 ms 10 ms 0,1-440 Hz 500 V/µs 50 A/µs 1500 A2s 2kV crit B 2kV crit B gRC 25A/32A/50A/63A 14x51 VRMS VRMS MΩ V 4000 4000 100 (@500VDC) 4000 IP20 2 1,5 30/50 -30 /+80 -30/+100 40 to 85 260 EN60947-4-3 (IEC947-4-3) EN60950 UL/cUL pending mm g °C °C % g celduc r e l a i s www.celduc.com Rue Ampère B.P. 4 42290 SORBIERS - FRANCE E-Mail : [email protected] Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19 celpac® Thermal specifications . Current according ambient temperature : Ø The curve "1" gives the limits of the product. The temperature reached are acceptable for the components. These values are in compliance with most of SSRs manufacturers. In a cabinet with a minimum of ventilation or a non permanent current, these values are correct. Ø The curve "2" gives the limits of the product according to EN60947-4-3 with a maximum rise temperature of 50°C (@40°C) for a permanent working and in air calm ( test during 8 hours). Ø For a non permanent current, you can calcule the average power = Pd x duty cycle and check the rise temperature : Tj = Pd x Rthj/a (Pd and Rthj/a are given page 2)). The junction temperature must not exceed 125°C at the maximum ambient temperature. www.DataSheet4U.com The maximum current is limited to the size of the thyristors = 50A. Ø The thermal constant (Cth) of the product is 7 minutes. That means the rise temperature is only 63% of the stabilized temperature after a running time of 7 minutes. 45 40 35 30 I(A) 25 20 15 10 5 0 0 S/CLP/SIL855160/B/21/04/2004 page 3 / 4/GB 1 2 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Tambient(°C.


SIL842970 SIL855160 VD5026


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)