Document
®
BTA/BTB12 and T12 Series
12A TRIACS
SNUBBERLESS™, LOGIC LEVEL & STANDARD
MAIN FEATURES:
Symbol IT(RMS) VDRM/VRRM IGT (Q ) 1 Value 12 600 and 800 5 to 50 Unit A V mA
A1
G
A2
A1
A2
DESCRIPTION Available either in through-hole or surface-mount packages, the BTA/BTB12 and T12 triac series is suitable for general purpose AC switching. They can be used as an ON/OFF function in applications such as static relays, heating regulation, induction motor starting circuits... or for phase control operation in light dimmers, motor speed controllers,... The snubberless versions (BTA/BTB...W and T12 series) are specially recommended for use on inductive loads, thanks to their high commutation performances. Logic level versions are designed to interface directly with low power drivers such as microcontrollers. By using an internal ceramic pad, the BTA series provides voltage insulated tab (rated at 2500V RMS) complying with UL standards (File ref.: E81734)
www.DataSheet4U.com
A2 G
D2PAK (T12-G)
A2
A1 A2 G
A1 A2 G
TO-220AB Insulated (BTA12)
TO-220AB (BTB12)
ABSOLUTE MAXIMUM RATINGS
Symbol IT(RMS) Parameter RMS on-state current (full sine wave) D²PAK/TO-220AB TO-220AB Ins. ITSM Non repetitive surge peak on-state current (full cycle, Tj initial = 25°C) I²t Value for fusing Critical rate of rise of on-state current IG = 2 x IGT , tr ≤ 100 ns F = 50 Hz F = 60 Hz Tc = 105°C 12 Tc = 90°C t = 20 ms t = 16.7 ms 120 126 78 Tj = 125°C Tj = 25°C Tj = 125°C Tj = 125°C 50 VDRM/VRRM
+ 100
Value
Unit A A
I ²t dI/dt
tp = 10 ms F = 120 Hz tp = 10 ms tp = 20 µs
A² s A/µs V A W °C 1/7
VDSM/VRSM Non repetitive surge peak off-state voltage IGM PG(AV) Tstg Tj Peak gate current Average gate power dissipation Storage junction temperature range Operating junction temperature range
4 1 - 40 to + 150 - 40 to + 125
September 2002 - Ed: 6A
BTA/BTB12 and T12 Series
ELECTRICAL CHARACTERISTICS (Tj = 25°C, unless otherwise specified)
s
SNUBBERLESS™ and LOGIC LEVEL (3 Quadrants)
Symbol Test Conditions Quadrant T12 T1235 IGT (1) VGT VGD IH (2) IL dV/dt (2) VD = 12 V RL = 30 Ω I - II - III I - II - III I - II - III MAX. MAX. MIN. MAX. I - III II VD = 67 %VDRM gate open Tj = 125°C Tj = 125°C Tj = 125°C Tj = 125°C (dV/dt)c = 10 V/µs Without snubber MIN. MIN. MAX. 35 50 60 500 6.5 10 10 15 20 3.5 1 35 TW 5 SW 10 1.3 0.2 15 25 30 40 6.5 2.9 35 50 60 500 6.5 50 70 80 1000 12 V/µs A/ms BTA/BTB12 CW 35 BW 50 mA V V mA mA Unit
VD = VDRM RL = 3.3 kΩ Tj = 125°C IT = 100 mA IG = 1.2 IGT
(dI/dt)c (2) (dV/dt)c = 0.1 V/µs
s
STANDARD (4 Quadrants)
Symbol Test Conditions Quadrant BTA/BTB12 C IGT (1) VD = 12 V VGT VGD IH (2) IL dV/dt (2) VD = VDRM RL = 3.3 kΩ Tj = 125°C IT = 500 mA IG = 1.2 IGT VD = 67 %VDRM gate open Tj = 125°C Tj = 125°C I - III - IV II MIN. MIN. (dV/dt)c (2) (dI/dt)c = 5.3 A/ms RL = 30 Ω I - II - III IV ALL ALL MAX. MAX. MIN. MAX. MAX. 25 40 80 200 5 25 50 1.3 0.2 50 50 100 400 10 V/µs V/µs B 50 100 mA V V mA mA Unit
www.DataSheet4U.com
STATIC CHARACTERISTICS
Symbol VT (2) Vto (2) Rd (2) IDRM IRRM
Note 1: minimum IGT is guaranted at 5% of IGT max. Note 2: for both polarities of A2 referenced to A1
Test Conditions ITM = 17 A tp = 380 µs Tj = 25°C Tj = 125°C Tj = 125°C Tj = 25°C Tj = 125°C MAX. MAX. MAX. MAX.
Value 1.55 0.85 35 5 1
Unit V V mΩ µA mA
Threshold voltage Dynamic resistance VDRM = VRRM
2/7
BTA/BTB12 and T12 Series
THERMAL RESISTANCES
Symbol Rth(j-c) Rth(j-a) Junction to case (AC) Parameter D²PAK/TO-220AB TO-220AB Insulated Junction to ambient S=1 cm² D²PAK TO-220AB TO-220AB Insulated
S = Copper surface under tab
Value 1.4 2.3 45 60
Unit °C/W
°C/W
PRODUCT SELECTOR
Voltage (xxx) Part Number 600 V BTA/BTB12-xxxB BTA/BTB12-xxxBW BTA/BTB12-xxxC BTA/BTB12-xxxCW BTA/BTB12-xxxSW BTA/BTB12-xxxTW T1235-xxxG
BTB: non insulated TO-220AB package
Sensitivity 800 V X X X X X X X 50 mA 50 mA 25 mA 35 mA 10 mA 5 mA 35 mA X X X X X X X
Type Standard Snubberless Standard Snubberless Logic level Logic Level Snubberless
Package TO-220AB TO-220AB TO-220AB TO-220AB TO-220AB TO-220AB D²PAK
ORDERING INFORMATION
BT A 12 TRIAC SERIES
www.DataSheet4U.com
600
BW
(RG)
PACKING MODE Blank: Bulk RG: Tube
INSULATION: A: insulated B: non insulated CURRENT: 12A
VOLTAGE: 600: 600V 800: 800V
SENSITIVITY & TYPE B: 50mA STANDARD BW: 50mA SNUBBERLESS C: 25mA STANDARD CW: 35mA SNUBBERLESS SW: 10mA LOGIC LEVEL TW: 5mA LOGIC LEVEL
T 12 35
TRIAC SERIES CURRENT: 12A
-
600 G
PACKAGE: G: D2PAK
(-TR)
VOLTAGE: 600: 600V 800: 800V SENSITIVITY: 35: 35mA
PACKING MODE: Blank: Tube -TR: Tape & Reel
3/7
BTA/BTB12 and T12 Series
OTHER INFORMATION
Part Number BTA/BTB12-xxxyz BTA/BTB12-xxxyzRG T1235-xxxG T1235-xxxG-TR Marking BTA/BTB12-xxxyz BTA/BTB12-xxxyz T1235xxxG T1235xxxG Weight 2.3 g 2.3 g 1.5 g 1.5 g Base quantity 250 50 50 1000 Packing mode Bulk Tube Tube Tape & reel
Note: xxx = voltage, yy = sensitivity, z = type
Fig. 1: Maximum power dissipation versus RMS on-state current (full cycle).
P (W) 16 14 12 10 8 6 4 2 0 0 1 2 3 4
IT(RMS)(A).