DC-DC / Industry Standard Isolated Quarter Brick
Astec Industry Standard
75 Amps
AEQ75Y48
High Efficiency Quarter Brick
Total Power: Input Voltages: No. of Outputs:
1...
Description
Astec Industry Standard
75 Amps
AEQ75Y48
High Efficiency Quarter Brick
Total Power: Input Voltages: No. of Outputs:
135W 48V Single
Electrical Specs
Input
Input Range Input Surge Efficiency 36 to 75 VDC 100V /100ms 89% typical
Output
Output Current Line/Load Regulation Noise/Ripple Remote sense Transient Response 75A max <0.15%Vo typical 25mV typical Up to 10% of Vo 4% deviation typical 50% to 75% Load change 0.1A/µs Slew Rate 100µs recovery 120% Vo (autorecovery) 110% Io (autorecovery) 500kHz
Special Features
High Efficiency Baseplate construction Industry standard package 1.45" x 2.30" Redundant output power pins Startup and stable operation at high capacitive load Remote sense compensation Regulation to zero load Fixed frequency switching Basic insulation EU Directive 2002/95/EC Compliant for RoHS Overvoltage Protection Current Limit Switching Frequency
Control
Voltage Adjust Enable 90 to 110% Vo TTL compatible (Positive or Negative Logic options)
Environmental
Operating temperature range: -40°C to +105°C Baseplate Storage temperature: -40°C to +125°C Overtemperature protection: 115°C PCB temperature (Typical) MTBF: > 1 million hours
Safety
UL, cUL 60950 TUV EN60950
1
North America (USA): 1-888-41-ASTEC
Europe (UK): 44 (1384) 842-211
Asia (HK): 852-2437-9662
AMERICAS 5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698
EUROPE Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, ...