DatasheetsPDF.com

XLU12 Dataheets PDF



Part Number XLU12
Manufacturers EDI
Logo EDI
Description HIGH VOLTAGE RECOVERY
Datasheet XLU12 DatasheetXLU12 Datasheet (PDF)

XL XLR XLU XMR XMU HIGH VOLTAGE RECOVERY FOR X-RAY AND INDUSTRIAL APPLICATIONS STANDARD AND FAST RECOVERY TYPES EPOXY MOLDED PACKAGE PLATINUM DOPED AVALANCHE CAPABILITY www.DataSheet4U.com X-RAY BOARD ASSEMBLIES ALSO A VAILABLE. INQUIRE. ELECTRICAL CHARACTERISTICS (at TA=25 C Unless Otherwise Specified) o Type Peak Reverse Voltage, Operating, VR(OPER) Peak Reverse Voltage, Test, V R(TEST) Average Rectified Forward Current in o 55 C Oil (Fig. 1 ) Max. Peak Surge Current, I FRM 1/2 Cycles @ 60.

  XLU12   XLU12



Document
XL XLR XLU XMR XMU HIGH VOLTAGE RECOVERY FOR X-RAY AND INDUSTRIAL APPLICATIONS STANDARD AND FAST RECOVERY TYPES EPOXY MOLDED PACKAGE PLATINUM DOPED AVALANCHE CAPABILITY www.DataSheet4U.com X-RAY BOARD ASSEMBLIES ALSO A VAILABLE. INQUIRE. ELECTRICAL CHARACTERISTICS (at TA=25 C Unless Otherwise Specified) o Type Peak Reverse Voltage, Operating, VR(OPER) Peak Reverse Voltage, Test, V R(TEST) Average Rectified Forward Current in o 55 C Oil (Fig. 1 ) Max. Peak Surge Current, I FRM 1/2 Cycles @ 60Hz (Non Repetitive), Fig. 2 Max. Peak Surge Current, I FRM, 10 Cycles @ 60Hz Max. Forward Voltage Drop, VFM @ , l F XLR XL 5 5 5.5 200 35 11 10 9 10 XLR XLU XLR 10 9 10 12 11 12 20 XMR XMU XMU 5 5 5.5 5 10 9 10 18 20 5 5.5 kV kV mA AMPS AMPS 220 200 100 100 20 6 18 5.5 15 5 10 2.7 500 100 25 300 300 100 100 25 25 lF =50mA 7 12 1 14 1 22 1 28 1 l F=500mA lF =300mA 10 5 11 5 21 5 V A Max. DC Reverse Current, I RM , @ V R(TEST) and 25 oC, Max. DC Reverse Current, I RM , @ V R(TEST) and100 o C, Max. Reverse Recovery Time, TRR 1 30 25 30 30 30 500 350 350 A lF =50mA, l R =1 00mA, l RR =25mA,(Fig.4) 175 NOT RATED 175 50 175 150 75 75 ns Ambient Operating Temperature Range, T A Storage Temperature Range, TSTG -55 to +125oC -55 to +150oC If operated over 10,000 v/inch in length, devices should be immersed in oil or re-encapsulated. XL FIG.1 OUTPUT CURRENT vs AMBIENT TEMPERATURE XLR XLU XMR XMU FIG.2 NON- REPETITIVE SURGE CURRENT PEAK SURGE CURRENT VS NUMBER OF CYCLES AT 60 Hz O (SINE WA VE INPUT)AND T A=25 C 100 1 9 8 7 6 5 4 500 PEAK SURGE CURRENT(NON-REP), IFSM, (AMPS) AVG. FORWARD CURRENT IO (mA) XMR5 400 XMU XMR5 3 XMU 300 2 www.DataSheet4U.com 200 XL 10 XL 10 10 1 9 8 7 6 5 4 3 XLR 100 XLR XLU12 XLR20 XLU12 0 0 20 XLR20 2 40 50 8 100 120 140 1 O AMBIENT TEMPERATURE, T A(OIL) C 1 1 10 100 NUMBER OF CYCLES AT 60 Hz FIG.3 MECHANICAL Max.lead temperature for soldering, 1/8 from body ,10 seconds @260 OC 1.0 MIN. 0.38 MAX. 0.26 MAX. 1.0 MIN. 0.60 _ 0.010 + 0.180 0.052/0.048 DIA. TIN PLATED COPPER LEADS ALL DIMENSION IN INCHES 0.030/0.034 DIA. XMR,XMU XL,XLR,XLU FIG.4 REVERSE RECOVERY TEST METHOD RECOVERY WA VE FORM RECOVERY TEST CIRCUIT FORWARD CONDUCTION R1 +50mA T RR + PULSE GENERATOR IR IF TIME SWITCHING 50 OHM D.U.T. -25mA I RR R2 1 OHM SCOPE -100mA REVERSE RECOVERY CURRENT R1, R2 NON-INDUCTIVE RESISTORS PULSE GENERATOR-HEWLETT PACKARD 214A OR EQUIV. 1 KC REP.RATE, 10 SEC. PULSE WIDTH ADJUST PULSE AMPLITUDE FOR PEAK IR ELECTRONIC DEVICES, INC. DESIGNERS AND MANUFACTURERS OF SOLID STATE DEVICES SINCE 1951. 21 GRAY OAKS AVENUE * YONKERS. NEW YORK 10710 914-965-4400 * FAX 914-965-5531 * 1-800-678-0828 Ee-mail:[email protected] * Wwebsite: http://www.edidiodes.com .


XSUG68D XLU12 XLU5


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)