Document
G5S
PCB Relay
Compact Single-pole Relay for Switching Up To 5 A (Normally Open Contact), Ideal for Fan Control of Air Conditioners, and Heating Control of Small Appliances
www.DataSheet4U.com D Compact relay with high insulation between coil and
contacts.
D D
Up to 5A switching on the NO contacts. Ensures a withstand impulse voltage of 8,000 V between the coil and contacts. Class F coil insulation available. Conforms to UL, CSA, and IEC (TÜV).
D D
Ordering Information
Classification Single g contact SPDT SPST-NO Enclosure rating Plastic-sealed Plastic-sealed Model G5S-1 G5S-1A
Note: When ordering, add the rated coil voltage to the model number. Example: G5S-1 DC12 Rated coil voltage
J MODEL NUMBER LEGEND
G5S-jj-j-j-DCj 12 3 4
1. Contact Pole 1: Single pole
5
2. Contact Form nil = 1 form C A = 1 form A 3. Insulation class nil = standard CB = Class B CF = Class F 4. Enclosure nil = plastic sealed v = vented 5. Rated Coil Voltage 5, 9, 12, 18, 24, 48 VDC
1
PCB Relay
G5S
Specifications
J COIL RATINGS
Rated voltage Rated current Coil resistance Must operate voltage Must release voltage Max. voltage Power consumption 5 VDC 80 mA 62.5 Ω 9 VDC 44.4 mA 202.5 Ω 12 VDC 33.3 mA 360 Ω 18 VDC 22.2 mA 810 Ω 24 VDC 16.7 mA 1,440 Ω 48 VDC 8.3 mA 5,760 Ω
75% max. of rated voltage 5% min. of rated voltage 150% of rated voltage at 23°C, 110% of rated voltage at 70°C Approx. 400 mW
Note: Rated current and coil resistance are measured at 23°C with a tolerance of ±10%.
www.DataSheet4U.com
J CONTACT RATINGS
Load Rated load Resistive load 2 A (NO)/2 A (NC) at 277 VAC 5 A (NO)/3 A (NC) at 125 VAC 5 A (NO)/3 A (NC) at 30 VDC Ag 5 A (NO)/3 A (NC) 277 VAC, 30 VDC 5 A (NO)/3 A (NC) 625 VA, 150 W (NO) 375 VA, 90 W (NC) 10 mA at 5 VDC 1A 250 VA Inductive load 0.5 A at 250 VAC, cosφ=0.4 1 A at 250 VAC, cosφ=0.8 0.8 A at 250 VAC, cosφ=0.9
Contact material Rated carry current Max. switching voltage Max. switching current Max. switching capacity Min. permissible load
Note: P level: λ60=0.1 x 10 --6 operation (with an operating frequency of 120 operations/min.)
J CHARACTERISTICS
Contact resistance (See Note 2.) Operate time (See Note 3.) Release time (See Note 3.) Insulation resistance (See Note 4.) Dielectric strength Impulse withstand voltage Vibration resistance Shock resistance 100 mΩ max. 10 ms max. 5 ms max. 1,000 MΩ min. 4,000 VAC, 50/60 Hz for 1 min between coil and contacts 750 VAC, 50/60 Hz for 1 min between contacts of same polarity 8 kV (1.2 x 50 µs) Destruction: 10 to 55 Hz, 1.5-mm 1.5 mm double amplitude for 2 hours Malfunction: 10 to 55 Hz, 1.5-mm double amplitude for 5 minutes Destruction: 1,000 m/s2 (approx. 100G) Malfunction: Energized: 100 m/s2 (approximately 10G) Non-energized: 50 m/s2 (approximately 5G)
(This table continues on the next page.)
PCB Relay
G5S
2
Characteristics Table -- continued from previous page
Life expectancy Note 5.) p y (See ( ) Mechanical Electrical 5,000,000 operations (18,000 operations per hour) 200,000 operations: 1 A (NO)/1 A (NC) at 277-VAC resistive load 3 A (NO)/3 A (NC) at 125-VAC resistive load 100,000 operations: 0.8 A (NO)/0.8 A (NC) at 250 VAC, cosφ=0.9 5 A (NO)/3 A (NC) at 30-VDC resistive load 50,000 operations: 2 A (NO)/2 A (NC) at 277-VAC resistive load 5 A (NO)/3 A (NC) at 125-VAC resistive load 1,800 operations per hour --40°C to 70°C (--40°F to 158°F) with no icing or condensation --40°C to 85°C (class B) (--40°F to 185°F) 35% to 85% Approx. 8.0 g The data shown above are initial values. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method. The operating time is possible with the rated voltage imposed with no contact bounce at an ambient temperature of 23°C. The insulation resistance is possible between coil and contacts and between contacts of the same polarity at 500 VDC. The electrical life data items shown are possible at 23°C.
Switching frequency Ambient temperature Ambient humidity Weight www.DataSheet4U.com Note: 1. 2. 3. 4. 5. Operating & storage Operating & storage
J APPROVED STANDARDS
UL508 (File No. E41515) CSA C22.2 (No. 14) (File No. LR31928)
Model G5S-1 (-CB) G5S-1A (-CB) Coil ratings 5--48 VDC Contact ratings 0.5 A, 250 VAC (resistive) 2 A, 120 VAC (resistive) 2 A, 30 VDC (resistive) 5 A, 125 VAC (resistive) 1/10 HP, 125 VAC 5 A, 277 VAC (resistive) 1/6 HP, 277 VAC 0.3 A, 110 VDC (resistive) 5 A, 30 VDC (resistive) Number of test operations 6,000
TÜV (IEC 255, VDE0435 File No. R9650783)
Electrical life tests are performed at 70°C. Model G5S-1 (-CB) G5S-1A (-CB) Coil ratings 5,6,9,12,18,20,24,48 Contact ratings 1.5 A, 277 VAC (resistive) 1 A, 250 VAC (resistive) 2 A, 30 VDC (resistive) 1 A, 250 VAC, cosφ=0.8 0.5 A, 250 VAC, cosφ=0.4 1 A, 250 VAC, cosφ=0.8 (NO only) 1 A, 250 VAC, cosφ=0.8 (NC only) Note: Pollution Degree 2, Overvoltage Category II, Material Group III Number of test operations 30,000 100,000 30,000 100,000 30,000 200,000 200,000
3
PCB Relay
G5S
Engineering Data
J MAX. SWITCHING CAP.