TYPICAL PERFORMANCE
Horizontal: 0.5 MHz/div
Vertical (from top):
Magnitude 10,1 Phase 5
dB/div deg/div
SPECIFICATION
Parameter Center Frequency (Fc) Insertion Loss Lower 1.5 dB Frequency Upper 1.5 dB Frequency Lower 35 dB Frequency Upper 35 dB Frequency Ultimate Rejection at Fc ± 0.90 MHz Triple Transit Suppression Passband Amplitude Ripple Passband Phase Linearity 1 Operating Temperature Source and Load Impedance
Notes: 1. Over center 1.23 MHz.
Min
70.62 69.24 50 30
-5
Typ 69.99 20.2 69.35 70.63 69.25 70.73 55 40 0.5 4 23 50
Max 22 69.36 70.74
0.7 10 +65
Units MHz dB MHz MHz MHz MHz dB dB dB p-p deg p-p °C Ω
Rev X2 25-Jun-04
Page 1 of 2
69.99 MHz Filter for CDMA Applications
Part Number
SF0070CD21803T
Micro Networks, 324 Clark Street, Worcester, MA 01606, USA tel: 508-852-5400, fax:508-852-8456, www.icst.com
PACKAGE OUTLINE
Units:
mm
Pin Configuration: Input: 2 Output: 11 Output Return: 8 Ground: 1,3,4,5,6,7,9,10,12,13,14,15,16,17,18
MATCHING CIRCUIT
Cs1 Ls1 2 Cp1 16 8 11 Cp2 Ls2 Cs2
Typical component values: (minimum inductor Q = 50) Notes -
Ls1 = 150 nH ± 6% Ls2 = 150 nH ± 6%
Cp1 = 82 pF Cp2 = 68 pF
Cs1 = 47 pF Cs2 = 47 pF
-
Requires 2% matching components. Component values may change depending on board layout. ISO 9001 Registered Micro Networks