Document
www.DataSheet4U.com
Synthesizer , SMT 2496 — 2700 MHz, 1000 kHz
Features
♦ ♦ ♦ ♦
RoHS Compliant Fully Integrated VCO, PLL, Loop Filter High Performance, Low Cost Miniature SMT Package (LSM6)
MAVC-060103-132600
Rev: C
Description
This synthesizer design integrates a high performance VCO, PLL, IC and discrete loop filter in a surface mount package. This SMT package provides electrical shielding, easy PCB assembly and repeatable performance. The synthesizer is designed for use in wireless base stations. M/A-COM synthesizers are manufactured in an ISO9001 certified facility, incorporating surface mount assembly and automated electrical testing. This ensures consistent electrical performance and quality over volume production quantities.
Electrical Specifications1:
TA = +25°C, Z0 = 50 Ohms, Vcc1 = 5V, Vcc2 = 3.3V.
Parameter Frequency Range RF Output Power Phase Noise Test Conditions Over Top Over Top
2 2
Units MHz dBm dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc
Min 2500 -3.0
Typ
Max 2700 +3.0
SSB at 100 Hz offset from carrier SSB at 1 kHz offset from carrier SSB at 10 kHz offset from carrier SSB at 100 kHz offset from carrier SSB at 1 MHz offset from carrier
-84 -84 -91 -118 -138
-80 -80 -89 -116 -136 -20
Harmonic Suppression Spurious Suppression (Non-Harmonic) Reference feed through Frequency Lock Time VCO Supply Current (ICC1) PLL Supply Current (ICC2) VCO Power Supply (VCC1) PLL Power Supply (VCC2) Over Fout ,+/- 500Hz Recommended operating condition Recommended operating condition Recommended operating condition Recommended operating condition Phase comparison frequency Other spurious Output
dBc dBc dBc ms mA mA V V +4.75 3.1
-85 -90 -90 22 27 9 +5.0 3.3
-70 -80 -80 30 30 10 +5.25 3.5
1. All specification limits are indicated values @ +25 ºC and apply over Fout unless otherwise stated. 2. See “Absolute Maximum Ratings” for Top. 1
M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use. or application of any product(s) or information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266 • Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300 • Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298 Visit www.macom.com for additional data sheets and product information.
Synthesizer , SMT 2496 — 2700 MHz, 1000 kHz
Electrical Specifications1: (cont’d)
Parameter Step Size (ΔF) Reference Frequency (FR) PLL Programming PLL Lock Monitor Output Test Conditions Recommended operating limit 1.0 V pp ± 0.2V square wave with input filter
MAVC-060103-132600
Units kHz MHz
Min
Typ 1000
Max
10
100
3-wire serial CMOS IAW ADF4113, Charge Pump max current Logic high = VCC2 x 0.8 Min and Logic low = VCC2 x 0.2 Max Locked = VCC2 - 0.4 Min , Unlocked = 0.4V Max
Pin Configuration
Pin No. 1 2 3 4 5 6 7 Function VCC2 GND REF I/P GND VCC1 GND RF O/P Pin No. 8 9 10 11 12 13 14 Function GND Lock Detect Clock Data Load Enable GND GND
Absolute Maximum Ratings TA = +25°C
Parameter VCO Supply Voltage (VCC1) PLL Supply Voltage (VCC2) Reference Frequency Level Data, Clock, Strobe Voltages Operating Temperature Storage Temperature Solder Assembly Temperature Weight
TO CONTROLLER
Absolute Maximum -0.3V to 6.5 V -0.3V to 6.5 V -0.3V to 6.5 V -0.3V to Vcc + 0.3 V -40°C to +85°C -45°C to +120°C See App Note M2032 3.0 grams
2
Functional Block Diagram
Moisture Sensitivity Level ESD Rating
2 Class 1
13 1 10nF 2 GND DATA 11 GND VCC2 LOAD ENABLE 12
3
REF IN
CLOCK
10
1. Operation of this device above any one of these parameters may cause permanent damage. 2. As per JEDEC-STD-020.
4
GND
LOCK DETECT
9
Environmental Specifications
Devices are designed to function after exposure to the shock, vibration, thermal shock and moisture conditions typically encountered in base station and other infrastructure environments.
50R
5 10nF 6
VCC1
GND
8
GND GND 14
RF OUT
7
Ordering Information
1. The diagram above shows a typical application. 2. The Reference input and RF output are internally AC coupled. 3. The diagram applies when digital lock detect is selected. For analog open-drain mode, a filter is required. Part Number MAVC-060103-132600 1. See application note M513. Package Tape and Reel (300/Reel) 1
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use. or application of any product(s) or information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266 • Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300 • Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298 Visit www.macom.c.