Air sensor
Temperature Measurement Probe Assemblies
Applications
I Air sensor for air conditioning (not for use in evaporator)
B57...
Description
Temperature Measurement Probe Assemblies
Applications
I Air sensor for air conditioning (not for use in evaporator)
B57500 M 500
5 max.
15 max.
Features
I Thermistor with epoxy resin encapsulation I PVC-insulated wires (black)
Epoxy resin
500±20
with tinned ends, AWG 26, Tmax = 105 °C Options Alternative resistance ratings, rated temperatures, resistance tolerances and wire lengths, AWG 22 or AWG 24 available on request Delivery mode Bulk
Twin wire AWG26 PVC insulation
6±1,5
TNT0399-N
Dimensions in mm
Climatic www.DataSheet4U.com
category (IEC 60068-1) Max. power at 25 °C Resistance tolerance Rated temperature B value tolerance Dissipation factor (in air) Thermal cooling time constant (in air) Heat capacity Insulation resistance (V = 100 Vdc) Test voltage (t = 1 s)
P25 ∆R N/R N TN ∆B/B δth τc Cth Ris VT
30/100/56 60 ±3% 25 ± 0,5 % approx. 3 approx. 20 approx. 60 > 100 1,25
mW
°C
mW/K s mJ/K MΩ kVAC
R 25
No. of R/T characteristic 8016
B 25/100 K 3988
Ordering code
Ω
10 k
B57500M0103A005
Note Only to use in dry environmental conditions.
116 05/02
Temperature Measurement Probe Assemblies
Reliability data Test Storage in dry heat Standard IEC 60068-2-2 Test conditions Storage at upper category temperature T: 100 °C t: 1000 h Temperature of air: 40 °C Relative humidity of air: 93 % Duration: 56 days Storage at lower category temperature T: – 30 °C t: 1000 h IEC 60068-2-14
B57500 M 500
∆R 25/R25 (typical)
<2%
Remarks No visible damage
Storage in damp h...