DatasheetsPDF.com

TEW5362

Filtran

CEPT/T1 Output Transformer

www.DataSheet4U.com CEPT/T1 TEW5362 is is designed and approved to be used as a transmit transformer in T1/CEPT applica...


Filtran

TEW5362

File Download Download TEW5362 Datasheet


Description
www.DataSheet4U.com CEPT/T1 TEW5362 is is designed and approved to be used as a transmit transformer in T1/CEPT applications with the following devices: – – – Dallas PMC-Sirerra AT&T DS2186 DS2153Q PM4341 T1X PM6431 E1 T7290 Output Transformer Typical applications are: Wide temperature range. Primary rate ISDN network nodes. PBX or computer to T1/CEPT Digital trunks. TDM Multiplexers. TEW5362 MECHANICAL 5 4 3 Line 2 8 1 Device 0.060" 0.047" Grid, 0.1" x 0.1" ELECTRICAL SPECIFICATION Line Impedance TEW5362 TEW5362-1 100 & 120 Ω TEW5362-2 75 Ω 0.65 0.55 > 0.9 < 0.8 0.5 : 0.5 : 1 I.431 CEPT 1500 DCR Inductance Leakage Ind. Turns Ratio Longitudinal Bal. Pulse Shape (Ohms) (mH) (µ H) (1-2) + (3-4) (5-8) (5-8) (5-8) (1-2) : (3-4) : (5-8) 0.65 0.75 > 1.8 < 1.0 0.5 : 0.5 :1.36 T1.408 & I.431 T1 & CEPT 1500 ISSUE: C 97/04/14 Dielectric Strength (Vrms) Temperature Operating Storage to 85 C -55 to 105o C -40o o o Filtran Limited 229 Colonnade Road, Nepean, Ontario, Canada. K2E 7K3, Tel : (613) 226-1626 Fax : (613) 226-7124 2-40 ...




Similar Datasheet