CEPT /T1 Output Transformer
www.DataSheet4U.com
CEPT /T1
TEW4921 is designed and approved to be used as a transmit transformer with the Mitel MT897...
Description
www.DataSheet4U.com
CEPT /T1
TEW4921 is designed and approved to be used as a transmit transformer with the Mitel MT89760/-60B and MT89790/90B devices in T1 and CEPT applications. Complies with ANSI T1.408 and CCITT I.431., with regards to Longitudinal Balance. TEW4921-2 is designed for MT89790B when operating from a single 5 Vdc supply.
Output Transformer
Typical applications are: Primary rate ISDN network nodes. PBX or computer to T1/CEPT Digital Trunks. TDM Multiplexers.
TEW4921
Fully encapsulated in epoxy. BABT certified for reinforced insulation to EN60950 & EN41003. Cert #: CR/T/0052
MECHANICAL 6 Line side 4 TEW4921 & -1 6
WHITE DOT AT PIN 1
1 2 3 Device
1 2 3 TEW4921-2 Device
Line side
5 4
ELECTRICAL SPECIFICATIONS Impedance
TEW4921.chp
TEW4921 100 & 120 Ω
TEW4921-1 75 Ω 3.5 0.25 1 : 1 : 0.39 n/a > 0.57 CEPT > 40 dB 4000 V
TEW4921-2 75/120 Ω 3.5 0.35 1 : 1 : 1.37 1 : 1 : 1.12 > 1.5 CEPT > 40 dB 4000 V
DCR Turns ratio Inductance
(Ohms)
(1 - 3) (6 - 4) (1-2):(2-3):(6 -4) (1-2):(2-3):(6 -5)
3.5 0.35 1 : 1 : 0.53 n/a > 1.0 T1 & CEPT
94/11/02
(mH)
(6 - 4)
ISSUE: E
Pulse Mask Longitud. Bal. (dB) 50 - 1544 KHz
> 40 dB 4000 V
Dielectric Strength, (Vrms) Temperatures Operating Storage 0o to 50o C -20o to 80o C
Filtran Limited
229 Colonnade Road, Nepean, Ontario, Canada. K2E 7K3, Tel : (613) 226 1626 Fax : (613) 226 7124
2-15
...