Document
www.DataSheet4U.com
Product Specification
R0605400L
Si Reverse, low current, 5 – 65MHz, 40.3dB typ. Gain @ 65MHz, 160mA max. @ 24VDC
FEATURES
• • • • • • Excellent linearity Superior return loss performance Extremely low distortion Optimal reliability Low noise Unconditionally stable under all terminations
R0605400L
APPLICATION
• 5 to 65 MHz CATV amplifier for reverse channel systems Si Reverse Hybrid, low current 5 – 65 MHz 40.3dB typ. Gain @ 65MHz 160mA max. @ 24VDC
DESCRIPTION
• Hybrid reverse amplifier employing silicon die
LIMITING VALUES
In accordance with the Absolute Maximum Rating System (IEC 60134)
SYMBOL
Vi Vov Tstg Tmb
PARAMETER
RF input voltage (single tone) DC supply over-voltage (5 minutes) storage temperature operating mounting base temperature
MIN.
- 40 - 30
MAX.
50 30 + 100 + 100
UNIT
dBmV V °C °C
CHARACTERISTICS
Table 1: S-Parameter, Noise Figure, DC Current; VB = 24V; Tmb = 30°C; ZS = ZL = 75 Ω
SYMBOL
Gp SL FL S11 S22 S12 F Itot
PARAMETER
power gain slope 1) flatness of frequency response input return loss output return loss reverse isolation noise figure total current consumption (DC)
CONDITIONS
f = 5 MHz f = 65 MHz f = 5 to 65 MHz f = 5 to 65 MHz f = 5 to 65 MHz f = 5 to 65 MHz f = 5 to 65 MHz f = 5 to 65 MHz
MIN.
39.7 40.0 -0.1 -0.2 20.0 20.0 -
TYP.
40.1 40.3 0.2
MAX.
40.5 40.7 0.6 0.4 -40.0 4.5 160.0
UNIT
dB dB dB dB dB dB dB dB mA
145.0
Notes: 1) The slope is defined as the difference between the gain at the start frequency and the gain at the stop frequency.
Page 1 of 4
2005 Nov 16
Document Revision Level B
Product Specification
R0605400L
Si Reverse, low current, 5 – 65MHz, 40.3dB typ. Gain @ 65MHz, 160mA max. @ 24VDC
CHARACTERISTICS
Table 2: Distortion data 5 – 65 MHz; VB = 24V; Tmb = 30°C; ZS = ZL = 75 Ω
SYMBOL
CTB XMOD CSO d2 V0
Notes: 1) 2) 3)
PARAMETER
composite triple beat cross modulation composite second order distortion second order distortion output voltage
CONDITION
7 ch. flat; Vo = 50 dBmV
1)
MIN.
-
TYP.
MAX.
- 72 - 64 - 70 - 70
UNIT
dBc dB dBc dBc dBmV
7 ch. flat; Vo = 50 dBmV 1) 7 ch. flat; Vo = 50 dBmV 1)
2)
Dim = -60 dB
3)
62.0
-
7 channels, US frequency raster: T7 – T13 (7.0 to 43.0 MHz), +50 dBmV flat output level. f1 = 7.00 MHz; V1 = 50 dBmV; f2 = 25.00 MHz; V2 = 50 dBmV; fTEST = f1 + f2 = 32.0 MHz. f1 = 13.00 MHz; V1 = 50 dBmV; f2 = 25.00 MHz; V2 = V1 – 6dB; f3 = 7.00 MHz; V3 = V1 – 6dB; fTEST = f1 + f2 - f3 = 31.00 MHz, according to DIN45004B.
Composite Second Order (CSO) The CSO parameter (both sum and difference products) is defined by the NCTA. Composite Triple Beat (CTB) The CTB parameter is defined by the NCTA. Cross Modulation (XMOD) Cross modulation (XMOD) is measured at baseband (selective voltmeter method), referenced to 100% modulation of the carrier being tested.
Page 2 of 4
2005 Nov 16
Document Revision Level B
Product Specification
R0605400L
Si Reverse, low current, 5 – 65MHz, 40.3dB typ. Gain @ 65MHz, 160mA max. @ 24VDC
I U
123 5 7 89
E J S T P K
C M O Q N B R
øG
D H L F A
All Dimensions in mm:
nominal A B C D E F G 44,6 ± 0,2 13,6 ± 0,2 20,4 ± 0,5 8 ± 0,15 12,6 ± 0,15 38,1 ± 0,2 4 +0,2 / -0,05 4 ± 0,2 25,4 ± 0,2 UNC 6-32 4,2 ± 0,2 27,2 ± 0,2 11,6 ± 0,5 5,8 ± 0,4 0,25 ± 0,02 0,45 ± 0,03 2,54 ± 0,3 2,54 ± 0,5 2,54 ± 0,25 5,08 ± 0,25 5,08 ± 0,25 min 44,4 13,4 19,9 7,85 12,45 37,9 3,95 3,8 25,2 4,0 27,0 11,1 5,4 0,23 0,42 2,24 2,04 2,29 4,83 4,83 max 44,8 13,8 20,9 8,15 12,75 38,3 4,2 4,2 25,6 4,4 27,4 12,1 6,2 0,27 0,48 2,84 3,04 2,79 5,33 5,33
Pinning:
0 5 10mm scale
INPUT GND GND GND GND +VB
1
2
3 4 5 6 7
8
9
OUTPUT
H I J K L M N O
Notes:
European Projection
P Q R S T U
Page 3 of 4
2005 Nov 16
Document Revision Level B
Product Specification
R0605400L
Si Reverse, low current, 5 – 65MHz, 40.3dB typ. Gain @ 65MHz, 160mA max. @ 24VDC
DEFINITIONS Data Sheet Status Objective Product Specification Preliminary Product Specification Product Specification Limiting values Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 60134). Stress above one or more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation of the device at these or at any other conditions above those given in the Characteristics sections of the specification is not implied. Exposure to limiting values for extended periods may affect device reliability. Application information Where application information is given, it is advisory and does not form part of the specification.
Premier Devices reserves the right to make changes without further notice to any products herein. Premier Devices makes no warranty representation or guarantee regarding the suitability of its products for any particular purpose, nor does Premier Devices assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation consequential or incidental damages. “Typical” para.