Document
Data Sheet
Multisupply Supervisor/Sequencer with ADC and Temperature Monitoring ADM1063
MUX 04632-001
FEATURES
Complete supervisory and sequencing solution for up to 10 supplies
10 supply fault detectors enable supervision of supplies to <0.5% accuracy at all voltages at 25°C <1.0% accuracy across all voltages and temperatures
5 selectable input attenuators allow supervision of supplies to 14.4 V on VH 6 V on VP1 to VP4 (VPx)
5 dual-function inputs, VX1 to VX5 (VXx) High impedance input to supply fault detector with thresholds between 0.573 V and 1.375 V General-purpose logic input
10 programmable driver outputs, PDO1 to PDO10 (PDOx) Open-collector with external pull-up Push/pull output, driven to VDDCAP or VPx Open collector with weak pull-up to VDDCAP or VPx Internally charge-pumped high drive for use with external N-FET (PDO1 to PDO6 only)
Sequencing engine (SE) implements state machine control of PDOx outputs State changes conditional on input events Enables complex control of .