(T300A Series) STANDARD SPECIFICATIONS
www.DataSheet4U.com
T300A SERIES (ECL)
STANDARD SPECIFICATIONS
05/00
FREQUENCY RANGE FREQUENCY ACCURACY @ + 25 C FREQ...
Description
www.DataSheet4U.com
T300A SERIES (ECL)
STANDARD SPECIFICATIONS
05/00
FREQUENCY RANGE FREQUENCY ACCURACY @ + 25 C FREQUECY STABILITY Vs. TEMPERATURE OPERATING TEMPERATURE RANGE INPUT VOLTAGE ( See Note Below ) INPUT CURRENT @ - 4.5 VDC OUTPUT LOAD SYMMETRY RISE & FALL TIMES ( 10% to 90% Level ) START-UP TIME FREQUENCY STABILITY Vs. VOLTAGE
o
10 MHz to 240 MHz + 0.0015% ( + 15 PPM ) See Options Below See Options Below - 4.5 VDC + 5% 50 mA Max. 100K Compatible 100 Ω to - 2.0 VDC 60/40% @ 50% Level 2 nS Max. 15 mS Max. + 0.0002% ( + 2 PPM ) Max. (for 5% change in Voltage)
0.025” 0.015”
0.200” Max. 0.250” 0.200”
0.020” 0.016” Pin 1 is identified with a Sq. Corner 0.254” 1 Max.
14
Ceramic Stand-off ( Optional ) 0.439” Max.
7
0.507” Max.
8
0.305” 0.155” 0.295” 0.145”
0.305” 0.295” 0.605” 0.595” 0.877” Max.
Pin Connections 14 7 8 1 All Others GND/CASE -4.5 VDC OUTPUT N/C MISSING
AGING @ +25 C PACKAGE, SEAL & LEAD FINISH
o
+ 0.0005% ( + 5 PPM ) / year Max. Conforms with the Requirements of MIL-PRF-55310
DataShee
DataSheet4U.com
NOTE: For PECL applications, Xsis 300 Series ECL oscillators can be operated with +5 VDC + 10% on Pin 14 and power supply return on Pin 7. The output logic levels will still be referenced to +5 VDC and the case will be at +5 VDC, however, 0.8 V peak to peak output signal can be AC or DC coupled as necessary.
Contact Xsis Engineering
for special requirements such as, Output Symmetry, Start-up Time, Frequency Accuracy, Complementary Outputs, M...
Similar Datasheet