5-6W, Ultra-Wide Input Range DIP, Single & Dual Output DC/DC Converters
Key Features
y y y y y y y y y y
Efficiency up to 83% 1500VDC Isolation MTBF > 1,000,000 Hours 4:1 Wide Input Range Low Cost Complies with EN55022 Class A Temperature Performance -40] to +71] Industry Standard Pinout UL 94V-0 Package Material Internal SMD Construction
Minmax's MIW4100-Series power modules operate over input voltage ranges of 9-36VDC and 18-75VDC which provide precisely regulated output voltages of 3.3V, 5V, 12V, 15V, {5V, {12V and {15VDC. The -40] to +71] operating temperature range makes it ideal for data communication equipments, mobile battery driven equipments, distributed power systems, telecommunication equipments, mixed analog/digital subsystems, process/machine control equipments, computer peripheral systems and industrial robot systems. The modules have a maximum power rating of 6W and a typical full-load efficiency of 83%, continuous short circuit, EN55022 Class A conducted noise compliance minimize design-in time, cost and eliminate the need for external filtering.
I/O Isolation
EN55022 Wide Range
$
Low Cost
High Power Density
More Power
1500 VDC
EMI
4:1
Block Diagram
Single Output
taS hee t4U .co
m
Dual Output
+Vin
LC Filter
+Vo
+Vin
LC Filter
+Vo Com.
-Vo Isolation Ref.Amp PFM Isolation Ref.Amp
-Vo
-Vin
PFM
-Vin
ww
w.D a
1
MINMAX
REV:0 2005/04
www.DataSheet4U.com
MIW4100 Series
Model Selection Guide
Model Number Input Voltage Output Voltage Output Current Input Current Reflected Ripple Current mA (Typ.) Efficiency
VDC MIW4121 MIW4122 MIW4123 MIW4124 MIW4125 MIW4126 MIW4127 MIW4131 MIW4132 MIW4133 MIW4134 MIW4135 MIW4136 MIW4137 48 ( 18 ~ 75 ) 24 ( 9 ~ 36 )
VDC 3.3 5 12 15 {5 {12 {15 3.3 5 12 15 {5 {12 {15
Max. mA 1200 1000 500 400 {500 {250 {200 1200 1000 500 400 {500 {250 {200
Min. mA 120 100 50 40 {50 {25 {20 120 100 50 40 {50 {25 {20
@Max. Load mA (Typ.) 220 267 301 305 267 301 305 110 134 151 152 134 151 152
@No Load mA (Typ.)
@Max. Load % (Typ.) 75 78 83
20
20
82 78 83 82 75 78 83
10
15
82 78 83 82
Absolute Maximum Ratings
Parameter Input Surge Voltage ( 1000 mS ) Internal Power Dissipation 24VDC Input Models 48VDC Input Models Min. -0.7 -0.7 ----Max. 50 100 260 2,500 Unit VDC VDC ] mW
Notes :
1. Specifications typical at Ta=+25], resistive load, nominal input voltage, rated output current unless otherwise noted. 2. Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%. 3. Ripple & Noise measurement bandwidth is 0-20 MHz. 4. These power converters require a minimum output loading to maintain specified regulation. 5. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed. Min. -40 -40 -40 --Free-Air Convection EN55022 Class A Max. +71 +95 +125 95 Unit ] ] ] % 6. All DC/DC converters should be externally fused at the front end for protection. 7. Other input and output voltage may be available, please contact factory. 8. Specifications subject to change without notice.
Lead Temperature (1.5mm from case for 10 Sec.)
ww w.D ata Sh eet 4U .co m
Parameter Operating Temperature Operating Temperature Storage Temperature Humidity Cooling Conducted EMI
Exceeding the absolute maximum ratings of the unit could cause damage. These are not continuous operating ratings.
Environmental Specifications
Conditions Ambient Case
REV:0 2005/04
MINMAX
2
www.DataSheet4U.com
MIW4100 Series
Input Specifications
Parameter Start Voltage Under Voltage Shutdown Reverse Polarity Input Current Short Circuit Input Power Input Filter All Models Model 24V Input Models 48V Input Models 24V Input Models 48V Input Models Min. 7 14 --------Typ. 8 16 --------Pi Filter Max. 9 18 8.5 16 1 3000 A mW VDC Unit
Output Specifications
Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Ripple & Noise (20MHz) Ripple & Noise (20MHz) Ripple & Noise (20MHz) Over Power Protection Transient Recovery Time Transient Response Deviation Temperature Coefficient Output Short Circuit 25% Load Step Change Over Line, Load & Temp. Dual Output, Balanced Loads Vin=Min. to Max. Io=10% to 100% Conditions Min. --------------110 ------Continuous Typ. {0.5 {0.5 {0.1 {0.5 50 ----250 300 {3 {0.01 Max. {2.0 {2.0 {0.5 {1.0 80 100 15 350 500 --{0.02 Unit % % % % mV P-P mV P-P mV rms % uS % %/]
General Specifications
Parameter Isolation Voltage Test Isolation Resistance Isolation Capacitance Switching Frequency MTBF Conditions 60 Seconds Flash Tested for 1 Second 500VDC 100KHz,1V MIL-HDBK-217F @ 25], Ground Benign Min. 1500 1650 1000 ----1000 Typ. ------350 450 --Max. ------550 ----Unit VDC VDC M[ pF KHz K Hours
Capacitive Load
taS hee t4U .co
Models by Vout
m
3.3V 470
Isolation Voltage
5V 470
12V 100
15V 100
{5V # 100
{12V # 100
{15V # 100
Unit uF
Maximum Capacitive Load # For each output
ww
w.D a
3
MINMAX