DatasheetsPDF.com

DC005NDC4 Dataheets PDF



Part Number DC005NDC4
Manufacturers ETC
Logo ETC
Description Ultra Low Pressure Sensors
Datasheet DC005NDC4 DatasheetDC005NDC4 Datasheet (PDF)

OCTOBER 1997 SURSENSE™ Ultra Low Pressure Sensors DCAL4 Series Ratiometric 4-Volt Output High Accuracy Compensation Full Scale Pressure Ranges 0 to 1 in. H2O to 0 to 30 in. H2O ± 0 to ± 1 in. H2O to ± 0 to ± 30 in. H2O DESCRIPTION The SURSENSE™ line of ultra low pressure sensors is based upon a proprietary, patent applied for technology designed to reduce all output offset or common mode errors. These sensors utilize a silicon, micromachined sensing element which features a unique stress conce.

  DC005NDC4   DC005NDC4


Document
OCTOBER 1997 SURSENSE™ Ultra Low Pressure Sensors DCAL4 Series Ratiometric 4-Volt Output High Accuracy Compensation Full Scale Pressure Ranges 0 to 1 in. H2O to 0 to 30 in. H2O ± 0 to ± 1 in. H2O to ± 0 to ± 30 in. H2O DESCRIPTION The SURSENSE™ line of ultra low pressure sensors is based upon a proprietary, patent applied for technology designed to reduce all output offset or common mode errors. These sensors utilize a silicon, micromachined sensing element which features a unique stress concentration enhanced structure to provide a highly stable linear output that is proportional to applied pressure. Output offset errors due to changes in temperature, warm-up, long term stability and position sensitivity have all been significantly reduced when compared to conventional sensors. The DCAL series sensors provide a precision calibrated ratiometric 4 -volt output with SURSENSE enhanced stability. Each sensor features the precision calibration found in the DCX series with the addition of fully integrated signal conditioning in an industry standard package. Intended to operate from a fixed 5Vdc supply, the DCAL4 gage pressure sensors provide a 0.25v to 4.25v output while the differential versions provide a ± 2.0 volt output centered on a 2.25 volt zero pressure offset. These highly stable sensors are ideally suited for microprocessor or microcontroller based systems. APPLICATIONS s Medical Instrumentation s HVAC s Environmental Controls s Portable Monitors FEATURES s Available in Gage and Differential Pressure Ranges s Temperature Compensated over 0°C to 50°C s Position Sensitivity to ± 5mV/g s Warm-up drift < ± 5mV s Long Term Stability < ± 10mV s Combined Linearity and Hysteresis Error < ± 0.25%FS s Custom Calibration Available EQUIVALENT CIRCUIT VEXCITATION (1) PINOUT 1 VEXCITATION Common VOUTPUT VOFFSET – 2 VOUTPUT (3) + 3 4 VOFFSET (4) Common (2) DCAL Series SURSENSE™ Ultra Low Pressure Sensors DCAL401GN Ratiometric 4-Volt Output High Accuracy Compensation 1 in. H2O Full Scale Pressure MAXIMUM RATINGS PARAMETER MINIMUM MAXIMUM UNITS Operating Temperature Range Storage Temperature Proof Pressure Burst Pressure Supply Current Output Source Current Output Sink Current Excitation Voltage Common Mode Pressure –25 –40 100 200 85 125 °C °C in. H2O in. H2O 3 50 16 V psig ELECTRICAL SPECIFICATIONS PARAMETER, note 1 MINIMUM NORMAL MAXIMUM UNITS Operating Pressure Range, gage pressure Output Span, note 2 Offset Voltage Temperature Effect on Offset (0°C–50°C), note 3 Combined Temperature Effect on Span (0 °C–50°C), note 3 Offset Warm-up Shift, note 4 Offset Position Sensitivity (± 1g) Offset Long Term Drift (one year) Combined Linearity and Hysteresis Error, note 5 3.9 0.15 1.0 4.0 0.25 4.1 0.35 ± 60 ±2 ± 20 ± 10 ± 10 0.05 0.25 in. H2O V V mV %Span mV mV mV %FS Note 1: Reference conditions (unless otherwise noted): Supply Voltage, VS = 5V DC, TA = 25°C, Common Mode Line Pressure = 0 psig. Pressure measurements are with pressure applied to Port B. Note 2: The voltage added to the offset voltage at full scale pressure. Nominally the output voltage range is 0.25 to 4.25 volts. Note 3: Shift is relative to 25°C. Note 4: Shift is within the first hour of excitation applied to the device. Note 5: Measured at one-half full scale rated pressure using best straight line curve fit. DCAL Series SURSENSE™ Ultra Low Pressure Sensors DCAL401DN Ratiometric 4-Volt Output High Accuracy Compensation ± 1 in. H2O Full Scale Pressure MAXIMUM RATINGS PARAMETER MINIMUM MAXIMUM UNITS Operating Temperature Range Storage Temperature Proof Pressure Burst Pressure Supply Current Output Source Current Output Sink Current Excitation Voltage Common Mode Pressure –25 –40 100 200 85 125 °C °C in H2O in H2O 3 50 16 V psig ELECTRICAL SPECIFICATIONS PARAMETER, note 1 MINIMUM NORMAL MAXIMUM UNITS Operating Range, differential pressure Output Span, note 2 Offset Voltage @ zero differential pressure Temperature Effect on Offset (0°C–50°C), note 3 Combined Temperature Effect on Span (0 °C–50°C), note 3 Offset Warm-up Shift, note 4 Offset Position Sensitivity (± 1g) Offset Long Term Drift (one year) Combined Linearity and Hysteresis Error, note 5 ± 1.90 2.15 ± 1.0 ± 2.0 2.25 ± 2.10 2.35 ± 40 ±2 ± 20 ± 10 ± 10 0.05 0.25 in. H2O V V mV %Span mV mV mV %FS Note 1: Reference conditions (unless otherwise noted): Supply Voltage, VS = 5VDC, TA = 25°C, Common Mode Line Pressure = 0 psig. Pressure measurements are with pressure applied to Port B. Note 2: The voltage added to the offset voltage at full scale pressure. Nominally the output voltage range is 0.25 to 4.25 volts. Note 3: Shift is relative to 25°C. Note 4: Shift is within the first hour of excitation applied to the device. Note 5: Measured at one-half full scale rated pressure using best straight line curve fit. DCAL Series SURSENSE™ Ultra Low Pressure Sensors DCAL405GN Ratiometric 4-Volt Output High Accuracy Compensation 5 in. H2O Full Scale Pressure MAXIMUM RATINGS PA.


DC005 DC005NDC4 DC005NGC4


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)