Description Low-Power / Single/Dual-Level Battery Monitors
Datasheet MAX6434 DatasheetMAX6434 Datasheet (PDF)

19-2323; Rev 1; 9/03 Low-Power, Single/Dual-Level Battery Monitors with Hysteresis General Description The MAX6427–MAX6438 are single/dual-level battery monitors with internal hysteresis. These devices are offered with single (MAX6427/MAX6428/MAX6429, MAX6433/ MAX6434/MAX6435) or dual (MAX6430/MAX6431/ MAX6432, MAX6436/MAX6437/MAX6438) low-battery output indicators, which can be used to indicate three battery conditions: battery is good (operate system in normal mode), battery is weak (operate .

  MAX6434   MAX6434


Document
19-2323; Rev 1; 9/03 Low-Power, Single/Dual-Level Battery Monitors with Hysteresis General Description The MAX6427–MAX6438 are single/dual-level battery monitors with internal hysteresis. These devices are offered with single (MAX6427/MAX6428/MAX6429, MAX6433/ MAX6434/MAX6435) or dual (MAX6430/MAX6431/ MAX6432, MAX6436/MAX6437/MAX6438) low-battery output indicators, which can be used to indicate three battery conditions: battery is good (operate system in normal mode), battery is weak (operate system in low-power mode), or battery is empty (disable the system). These devices are ideal for monitoring single lithium-ion (Li+) cells or multicell alkaline/NiCd/NiMH power supplies. When the power-supply voltage drops below the specified low threshold, the low-battery output asserts. When the voltage rises above the specified high threshold, the lowbattery output is deasserted following a 140ms minimum timeout period. The timeout period ensures that the supply voltages have stabilized before power-converter or microprocessor activity is enabled. The MAX6427–MAX6438 family is available with several monitoring options. The MAX6427/MAX6428/MAX6429 offer factory-trimmed battery-monitor thresholds, with a single low-battery output. The MAX6430/MAX6431/MAX6432 also feature factory-trimmed thresholds, but have two lowbattery outputs. The MAX6433–MAX6438 have user-adjustable threshold voltages permitting the user to select the hysteresis range, and consequently the sensitivity of the system to noise. A wide hysteresis range also prevents chattering that can result due to battery recovery after load removal. Single low-battery outputs are supplied by the MAX6433/ MAX6434/MAX6435 and dual low-battery outputs by the MAX6436/MAX6437/MAX6438. The MAX6427–MAX6438 family is available with three output logic options for convenient interface with system power circuitry or microprocessors. The family is offered in small SOT23 and SOT143 packages and is fully specified over temperature. Features o Factory-Trimmed or User-Adjustable Threshold Options Factory-Trimmed Low Thresholds from 1.6V to 2.1V or 2.6V to 3.1V in 100mV Increments (MAX6427–MAX6432) Factory-Trimmed High Thresholds from 2.3V to 2.6V or 3.3V to 3.6V in 100mV Increments (MAX6427–MAX6432) User-Adjustable Low/High Thresholds with 615mV Internal Reference (MAX6433–MAX6438) o Low Current (1µA, typ) o Single or Dual Low-Battery Outputs o Push-Pull LBO, Open-Drain LBO, and Open-Drain LBO Options o 140ms Minimum LBO Timeout Period o Immune to Short Battery Voltage Transients o Guaranteed Valid LBO Logic State to BATT = 1.0V o -40°C to +85°C Operating Temperature Range o Small 3, 4, 5 and 6-Pin SOT Packages o No External Components Required (MAX6427–MAX6432) MAX6427–MAX6438 Ordering Information PART MAX6427_ _UR-T TEMP RANGE -40°C to +85°C PIN-PACKAGE 3 SOT23-3 Ordering Information continued at end of data sheet. †The MAX6427–MAX6432 are available with factory-trimmed battery-monitor thresholds. Select the desired thresholds using Tables 1 or 2 and enter the corresponding letters in the part number by replacing “_ _”. ________________________Applications Battery-Powered Systems (Single-Cell Li+ or Two/Three-Cell NiMH, NiCd, Alkaline) Cell Phones/Cordless Phones Portable Medical Devices Electronic Toys Pagers PDAs MP3 Players Note: There are 26 standard versions with a required order minimum of 2500 pieces. Sample stock is generally held on the standard versions only (see Standard Versions Table). Required order increment is 10,000 pieces for nonstandard versions. Contact factory for availability. All devices available in tape-and-reel only. Pin Configurations TOP VIEW LBO 1 (LBO) MAX6427 MAX6428 MAX6429 BATT 2 3 GND SOT23-3 ( ) ARE FOR THE MAX6429. Typical Operating Circuit appears at end of data sheet. Pin Configurations continued at end of data sheet. 1 ________________________________________________________________ Maxim Integrated Products For pricing, delivery, and ordering information, please contact Maxim/Dallas Direct! at 1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com. Low-Power, Single/Dual-Level Battery Monitors with Hysteresis MAX6427–MAX6438 ABSOLUTE MAXIMUM RATINGS BATT, VDD to GND ................................................-0.3V to +6.0V HTHIN, LTHIN Inputs to GND.....................-0.3V to (VDD + 0.3V) Open-Drain LBO/LBO, LBOH/LBOH, LBOL/LBOL to GND .........................................-0.3V to +6.0V Push-Pull LBO/LBO, LBOH/LBOH, LBOL/LBOL to GND ................-0.3V to (BATT or VDD + 0.3V) Input Current (all pins) ........................................................20mA Output Current (all pins) .....................................................20mA Continuous Power Dissipation (TA = +70°C) 3-Pin SOT23-3 (derate 4.0mW/°C above +70°C) .......320mW 4-Pin SOT143-4 (derate 4.0mW/°C above +70°C) .....320mW 5-Pin SOT23-5 (derate 7.1mW/°C above +70°C) .......571mW 6-Pin SOT23-6 (derate 8.7mW/°C above +70°C) .......6.


MAX6433 MAX6434 MAX6435


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)