DatasheetsPDF.com

TF2-H-4.5V Dataheets PDF



Part Number TF2-H-4.5V
Manufacturers Matsushita Electric Works(Nais)
Logo Matsushita Electric Works(Nais)
Description SMALL POLARIZED RELAY WITH HIGH SENSITIVITY
Datasheet TF2-H-4.5V DatasheetTF2-H-4.5V Datasheet (PDF)

TESTING SMALL POLARIZED RELAY WITH HIGH SENSITIVITY TF-RELAYS • Minimal magnetic interference allows high density mounting • Sealed construction allows automatic cleaning • Self-clinching terminal also available 14 .551 9 .354 7.8 .307 FEATURES • High sensitivity: 80 mW Nominal operating power (Single side stable 3-12 V type) • Surge voltage withstand: 1500 V FCC Part 68 mm inch SPECIFICATIONS Contact Arrangement 2 Form C Initial contact resistance, max. 50 mΩ (By voltage drop 6 V DC 1 A) .

  TF2-H-4.5V   TF2-H-4.5V



Document
TESTING SMALL POLARIZED RELAY WITH HIGH SENSITIVITY TF-RELAYS • Minimal magnetic interference allows high density mounting • Sealed construction allows automatic cleaning • Self-clinching terminal also available 14 .551 9 .354 7.8 .307 FEATURES • High sensitivity: 80 mW Nominal operating power (Single side stable 3-12 V type) • Surge voltage withstand: 1500 V FCC Part 68 mm inch SPECIFICATIONS Contact Arrangement 2 Form C Initial contact resistance, max. 50 mΩ (By voltage drop 6 V DC 1 A) Contact material Gold-clad silver Nominal switching 1 A 30 V DC, 0.5 A 125 V AC capacity (resistive load) Max. switching power 30 W, 62.5 VA (resistive load) Rating Max. switching voltage 110 V DC, 125 V AC Max. switching current 1A Min. switching capacity f1 10 µA 10 mV DC 80 mW (3 to 12 V DC) Single side stable 140 mW (24 V DC) 260 mW (48 V DC) Nominal operating 55 mW (3 to 12 V DC) 1 coil latching power 100 mW (24 V DC) 110 mW (3 to 12 V DC) 2 coil latching 200 mW (24 V DC) Mechanical (at 180 cpm) 108 1 A 30 V DC resistive load Expected 2×105 life (min. operations) Electrical (at 20 cpm) 0.5 A 125 V AC resistive load 105 Note: f1This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. Characteristics Initial insulation resistance*1 Between open contacts Initial Between contact and breakdown coil voltage Between contact sets FCC surge voltage between open contacts Temperature rise*2 (at 20°C) Operate time [Set time]* (at 20°C) 3 Min. 1,000 MΩ (at 500 V DC) 750 Vrms for 1 min. (Detection current: 10 mA) 1,000 Vrms for 1 min. (Detection current: 10 mA) 1,000 Vrms for 1 min. (Detection current: 10 mA) 1,500 V Max. 50°C Max. 4 ms (Approx. 2 ms) [Max. 4 ms (Approx. 2 ms)] Max. 4 ms (Approx. 1 ms) [Max. 4 ms (Approx. 2 ms)] Min. 490 m/s2 {50 G} Min. 980 m/s2 {100 G} 176.4 m/s2 {18G}, 10 to 55 Hz at double amplitude of 3 mm 294 m/s2 {30G}, 10 to 55 Hz at double amplitude of 5 mm –40°C to +70°C –40°F to +158°F 5 to 85% R.H. Approx. 2 g .071 oz Release time [Reset time]*4 (at 20°C) Functional*5 Shock resistance Destructive*6 Functional*7 Vibration resistance Destructive Conditions for operation, transport and storage*8 (Not freezing and condensing at low temperature) Unit weight Remarks Ambient temperature Humidity * Specifications will vary with foreign standards certification ratings. Measurement at same location as "Initial breakdown voltage" section. *2 By resistive method, nominal voltage applied to the coil; contact carrying current: 1 A. *3 Nominal voltage applied to the coil, excluding contact bounce time. *4 Nominal voltage applied to the coil, excluding contact bounce time without diode. *5 Half-wave pulse of sine wave: 11 ms; detection time: 10 µs. *6 Half-wave pulse of sine wave: 6 ms. *7 Detection time: 10 µs. *8 Refer to 4. Conditions for operation, transport and storage mentioned in Cautions for use (Page 178). *1 ORDERING INFORM.


TF2-H-3V TF2-H-4.5V TF2-H-48V


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)