DatasheetsPDF.com

FARM1CN2 Dataheets PDF



Part Number FARM1CN2
Manufacturers Vicor Corporation
Logo Vicor Corporation
Description FARM Filter/ Autoranging Rectifier Module
Datasheet FARM1CN2 DatasheetFARM1CN2 Datasheet (PDF)

PRELIMINARY 45 Features • • • • • • • • • EMI filtering Choice of 500W or 750W modules 96% Efficiency Autoranging 115/230Vac input Microprocessor controlled Inrush current limiting Mini sized package Power fail signal Module enable Data Sheet FARM TM Filter/ Autoranging Rectifier Module Up to 1000 Watts Shown actual size: 2.28 x 2.2 x 0.5 in 57,9 x 55,9 x 12,7 mm Product Highlights The FARM (Filter/Autoranging Rectifier Module) is an AC front-end module which provides EMI filtering, autor.

  FARM1CN2   FARM1CN2


Document
PRELIMINARY 45 Features • • • • • • • • • EMI filtering Choice of 500W or 750W modules 96% Efficiency Autoranging 115/230Vac input Microprocessor controlled Inrush current limiting Mini sized package Power fail signal Module enable Data Sheet FARM TM Filter/ Autoranging Rectifier Module Up to 1000 Watts Shown actual size: 2.28 x 2.2 x 0.5 in 57,9 x 55,9 x 12,7 mm Product Highlights The FARM (Filter/Autoranging Rectifier Module) is an AC front-end module which provides EMI filtering, autoranging line rectification and inrush current limiting. The FARM is available in either 500/750W or 750/1000W models in a mini sized package measuring only 2.28" x 2.2" x 0.5". The FARM interfaces directly with worldwide AC mains and may be used with Vicor 1st or 2nd Generation 300V input DC-DC converters to realize an autoranging, high density, low profile switching power supply. The FARM includes a microcontroller that continuously monitors the AC line to control bridge/doubler operation. The user need only provide external capacitance to satisfy system hold-up requirements. Vicor 2nd Generation packaging technology offers flexible mounting options for various manufacturing processes. The FARM may be installed as a conventional leaded device for on-board applications, in-board for low profile, height restricted applications, socketed or surface mounted with optional ModuMate interconnect products. Absolute Maximum Rating Parameter L to N voltage L to N voltage +Out to –Out voltage B OK to –Out voltage EN to –Out voltage Mounting torque Pin soldering temperature Pin soldering temperature Rating 264 280 400 16 16 4-6(0.45-0.68) 500 (260) 750 (390) Unit Vac Vac Vdc Vdc Vdc in-lbs (N-m) °F (°C) °F (°C) Notes Continuous 100ms 6 each, 4-40 screw <5 sec; wave solder <7 sec; hand solder Thermal Resistance and Capacity Parameter Baseplate to sink; flat, greased surface Baseplate to sink; with thermal pad (P/N 20264) Baseplate to ambient Baseplate to ambient; 1000 LFM Min Typ 0.16 0.14 8.0 1.9 Max Unit °C/Watt °C/Watt °C/Watt °C/Watt Part Numbering FARM Product 1 Type 1 = 500/750W 2 = 750/1000W C Product Grade C = –20°C to +100°C T = –40°C to +100°C 1 Pin Style* 1= Short Pin 2= Long Pin S= Short ModuMate N= Long ModuMate 1 Baseplate 1 = Slotted 2 = Threaded 3 = Thru-hole *Pin styles S & N are compatible with the ModuMate interconnect system for socketing and surface mounting. Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 FARM, Filter/Autoranging Rectifier Module Rev. 4.7 Page 1 of 12 Set your site on VICOR at www.vicorpower.com PRELIMINARY Electrical Characteristics Electrical characteristics apply over the full operating range of input voltage, output power and baseplate temperature, unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate. Specifications apply for AC mains having up to 5% total harmonic distortion. MODULE INPUT SPECIFICATIONS (FARM1xxx, FARM2xxx) Parameter Operating input voltage Operating input voltage Input undervoltage AC line frequency AC line frequency Power factor Inrush current FARM1xxx FARM2xxx Input surge withstand 2kV –50 µs common mode 1kV –50 µs differential mode 47 47 0.60 Min 90 180 Typ Max 132 264 90 63 880 0.65 30 60 Amps Amps Unit Vac Vac Vac Hz Hz Notes Autoranging (doubler mode) Autoranging (bridge mode) No damage C–Grade T–Grade Typical line 264Vac peak line, cold start 264Vac peak line, cold start EN61000-4-5 MODULE OUTPUT SPECIFICATIONS FARM1xxx Parameter Output power Output power Efficiency, 120Vac Efficiency, 240Vac Output voltage Hold-up capacitance Min 0 0 94 94 250 96 96 370 1,800 Typ Max 500 750 Min 0 0 94 94 250 96 96 370 3,300 FARM2xxx Typ Max 750 1000 Unit Watts Watts % % Vdc µF 90-264Vac Notes 90-132Vac 180-264Vac SAFETY SPECIFICATIONS (FARM1xxx, FARM2xxx) Parameter Safety approvals Isolation voltage (in to out) Isolation voltage (I/O to baseplate) Leakage current None 1500 1.2 Volts, rms mA 264Vac Min Typ Max Unit Notes UL 1950, CSA 22.2 No. 950, TÜV, VDE, EN60950, CE Marked Isolation provided by DC-DC converter(s) Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 FARM, Filter/Autoranging Rectifier Module Rev. 4.7 Page 2 of 12 Set your site on VICOR at www.vicorpower.com PRELIMINARY Electrical Characteristics (continued) MODULE CONTROL SPECIFICATIONS Parameter AC Bus OK (B OK) Low state resistance Low state current High state voltage B OK true threshold B OK false threshold Module Enable (EN) Low state resistance Low state current High state voltage Enable threshold Disable threshold AC Bus OK - Module Enable, differential error* 14.8 235 185 15 15.0 240 190 17 195 20 15 50 15.2 Ω mA Vdc Vdc Vdc Vdc 150K internal pull up to 15Vdc (see Fig. 10) Output bus voltage Output bus voltage AC Bus OK and Module Enable thresholds track To negative output - Converters disabled 14.8 235 200 15.0 240 205 15 50 15.2 245 210 Ω mA Vdc Vdc Vdc To negative output - Bus normal Bus normal .


FARM1CN1 FARM1CN2 FARM1CN3


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)