Document
FEATURES
85/85 THB – Safety Agency Approved Metalized Polypropylene
APPLICATIONS
MPX for X2, Across the Line MPXB for In Series with Mains EMI Filters – Outdoor Applications
Operating Temperature Range Capacitance Tolerance AC voltage (50/60 Hz)
Dissipation Factor at 1 kHz and 25°C
Insulation Resistance @25°C (<70% RH) for 1 minute
at 100VDC applied
Self-Inductance
Dielectric Strength
Life Expectancy
Humidity test
Impulse voltage (24 pulses)
Capacitance temperature coefficient
Construction Electrodes Coating
Lead terminations
-40°C to +110°C
+10% or +20% at 1 kHz, 25°C
UL/CSA
ENEC
CQC
275/305
275/305
Tan δ
0.01uF≤Cn≤1.0 uF
1.0uF<Cn≤10.0 uF Cn>10.0 uF
305
≤0.1% ≤0.3% ≤0.4%
Capacitance
Terminal to Terminal
Terminal to Case
<0.33uF >0.33uF
15,000 MΩ 5,000 MΩxuF
>30000 MΩ at 100VDC >5000 MΩ at 500VDC
>30000 MΩ at 100VDC >5000 MΩ at 500VDC
<1 nano-Henry per mm of lead spacing and lead length
Terminal to Terminal Terminal to case
1312 V.