Document
LAL2009-51
Broadband Access Transformer
Designed to meet UL 60950 and EN 60950 requirements for supplementary insulation and 250V working voltage RoHS Compliant Excellent THD performance Operating Temperature -40°C to 85°C
OCL: Leakage Inductance:
D.C.R:
Hi-POT : Turn Ratio:
Electrical Specifications @25℃
PIN 1-5= 410uH ±10% @ 10KHz/0.1V/Ser.
PIN 1-5= 10uH Max. @ 100KHz/0.1V
PIN 1-4 = 790 mohm Max. PIN 2-5 = 790 mohm Max. PIN 9-6 = 450 mohm Max. PIN 10-7 = 350 mohm Max. PRI. – SEC. =1875VAC/60Hz/2Seconds/1mA PIN1-4 : PIN 10-6 = 1.6±2% :1
Dimensions (Units: mm)
Schematic
LAL**** LinkCom
X Data Code G
13.50±0.5
C
12.85±0.5 A
PIN1
B
10 6
D
51 PIN3 CUT OFF 2.50
10.00±0.5
10.00
3.5±1.0 12.50±0.5
F
2.50±0.5 E
0.65±0.2
SUGGESTED PAD LAYOUT
0.5
10
9
6
Mark
1.LAL****----LAL2009 2. X----PRODUCT LINE 3. DATE CODE----YYWW 4. G----RoHS
From Ver. A