xDSL Transformer
LinkCom Manufacturing Co.,Ltd
LAL0562-60
xDSL Transformer
Designed to meet UL 60950-1 and IEC 60950-1 requirements fo...
Description
LinkCom Manufacturing Co.,Ltd
LAL0562-60
xDSL Transformer
Designed to meet UL 60950-1 and IEC 60950-1 requirements for supplementary insulation RoHS Compliant Operating Temperature -40°C to +85°C
Electrical Specifications @25℃
Inductance:
PIN 1-4 = 400uH ±7% @ 10KHz/0.1V/Series (PIN 2-3 Short)
Leakage Inductance:
PIN 1-4 = 850nH Ref. @ 1MHz/0.1V (PIN 2-3, PIN 7-8-9-10 Short)
Turn Ratio:
PIN 1-4 : PIN 10-7 = 2.0±2% : 1 (PIN2-3,PIN8-9 Short)
T.H.D
PIN 1-4 to PIN 10-7= –87dB ref. @ 30KHz/3V (PIN 2-3,PIN 8-9 Short)
D.C.R
PIN 1-4 = 1.50 ohm Max. (PIN2-3 short) PIN 10-7 = 1.25 ohm Max. (PIN8-9 short)
Hi-POT :
PRI. – SEC. =1875VAC/60Hz/1Second/1mA
Dimensions
(Units:
Inches mm
, Unless otherwise specified, all tolerances are ±
.010 0.25
)
.043 1.10
.098 2.50
Part Number
LinkCom
6
.445 11.30
10
.683 17.36
51
TOP VIEW
PIN1 .119 3.03
SUGGESTED PAD LAYOUT
A
1.45.5010Max
.531
B 13.50
Max
D
.098 2.50
E
.020 0.50
C
1.24.9520Ref 1.66.3000Max
.005/0.12
T...