TO-8 CASCADABLE AMPLIFIERS
Rev. 5/10
AC1218 10 TO 1200 MHz AC1219 TO-8 CASCADABLE AMPLIFIERS
Typical Values
High Dynamic Range . . . . . . . . . ...
Description
Rev. 5/10
AC1218 10 TO 1200 MHz AC1219 TO-8 CASCADABLE AMPLIFIERS
Typical Values
High Dynamic Range . . . . . . . . . . . . . . . . . . . . . High Output Power . . . . . . . . . . . . . . . . . . . . . . . High Third Order I.P. . . . . . . . . . . . . . . . . . . . . . . High Performance Thin Film Standard Size TO-8 Package
AC1218
+114 dBm +19.0 dBm +32.0 dBm
AC1219
+117 dBm +22.0 dBm +33.0 dBm
AC1218/AC1219
TO-8 Package for Amplifiers
SPECIFICATIONS*
Parameter
Frequency (Min.) Small Signal Gain (Min.)
Gain Flatness (Max.)
Noise Figure (Max.)
SWR (Max.) Input/Output
Power Output (Min.) dBm @ 1dB comp. AC1218 AC1219
Reverse Isolation
DC Current (Max.) mA AC1218 AC1219
Typical
5-1250 MHz 11.5 dB
±0.2 dB
4.5 dB
< 1.5:1
12V 15V +16.0 +19.0 +20.0 +22.0
16.0 dB
Guaranteed* 0 to 50 °C -55 to +85 °C
10-1200 MHz 10.5 dB
10-1200 MHz 10.0 dB
±0.5 dB
±0.7 dB
5.5^ dB
6.5^ dB
1.8:1
2.0:1
12 V 15V +15.0 +17.5 +17.5 +20.5
12V 15V +14.5 +17.0 +17.0 +20.0
——
45.0 65.0 70.0 88.0
50.0 68.0 75.0 93.0
53.0 71.0 78.0 96.0
* Measured in a 50-ohm system at +15 Vdc unless otherwise specified. ^ 1.0 dB higher above 700 MHz.
INTERMODULATION PERFORMANCE
Typical @ 25 °C; 600 MHz
AC1218
Second Order Harmonic Intercept Point . . . . . +51 dBm
Second Order Two Tone Intercept Point . . . . . . +45 dBm
Third Order Two Tone Intercept Point . . . . . . . . +33 dBm
AC1219
+43 dBm +37 dBm +32 dBm
AS1218/AS1219
SMTO-8 Package for Amplifiers
ABSOLUTE MAXIMUM RATINGS
Storage Temperat...