Description HOUR METER
Datasheet TH2356 DatasheetTH2356 Datasheet (PDF)

HOUR METER TH13·TH23 Hour Meters 52 2.047 52 2.047 54 2.126 mm inch TH23 series (with reset function) UL File No.: E42876 CSA File No.: LR39291 Features 1. High-performance compact synchronous motor The accurately turning motor is employed to provide for longer period of measurement. 2. Compact and stylish 3. Easier wiring The flat terminals (#187) are quick and easy to connect. 4. Rotary indicator The rotary indicator makes one turn every 2 minutes for monitoring. 5. Compliant with UL, C.

  TH2356   TH2356


Document
HOUR METER TH13·TH23 Hour Meters 52 2.047 52 2.047 54 2.126 mm inch TH23 series (with reset function) UL File No.: E42876 CSA File No.: LR39291 Features 1. High-performance compact synchronous motor The accurately turning motor is employed to provide for longer period of measurement. 2. Compact and stylish 3. Easier wiring The flat terminals (#187) are quick and easy to connect. 4. Rotary indicator The rotary indicator makes one turn every 2 minutes for monitoring. 5. Compliant with UL, CSA and CE. Typical applications Maintenance management of machine tools, automated machines, control panels, forming machines, medical equipment, generators, compressors, water treatment facilities, presses, motors, etc. TH13 series (without reset function) RoHS Directive compatibility information http://www.nais-e.com/ Specifications Rated operating voltage Allowable operating voltage range Rated frequency Counting range Minimum time display Rated power consumption Insulation resistance (Initial value) Breakdown voltage (Initial value) Max. temperature rise Vibration resistance Functional Shock resistance Functional Destructive Ambient temperature Ambient humidity Weight 100V AC, 200V AC, 110V AC, 115 to 120V AC, 220V AC, 240V AC 85 to 115% of rated operating voltage 50 Hz, 60 Hz (other model) 0 to 99999.9 hours (TH13 series) 0 to 9999.9 hours (TH23 series) 0.1 hours (6 min) Approx. 1.5 W Min. 100 MΩ, Between live and dead metal parts (At 500V DC) 2,000 Vrms, Between live and dead metal parts 55°C 131°F 10 to 55 Hz: 1 cycle/min double amplitude of 0.5 mm (10 min on 3 axes) Min. 98 m/s2 {10 G} (4 times on 3 axes) Min. 980 m/s2 {100 G} (5 times on 3 axes) –10 to +50°C +14 to 122°F Max. 85% RH (non-condensing) 135 g 4.76 oz 130 g 4.59 oz Product types Type Operating voltage Part number 50Hz 60Hz Operating voltage Part number 50Hz 60Hz TH13 types (without reset button) 100V AC 200V AC 110V AC TH1345 TH1355 TH1365 TH1346 TH1356 TH1366 115V AC (115 to 120V AC) 220V AC 240V AC TH1375 TH1385 TH1395 TH1376 TH1386 TH1396 TH23 types (with reset button) 100V AC 200V AC 110V AC TH2345 TH2355 TH2365 TH2346 TH2356 TH2366 115V AC (115 to 120V AC) 220V AC 240V AC TH2375 TH2385 TH2395 TH2376 TH2386 TH2396 Note) The 115 to 120V AC, 220V AC and 240V AC types are UL-recognized and CSA-certified. For those products, specify “U” at the end of the part number when ordering. 166 Applicable standard Safety standard EN61010-1 (EMI)EN61000-6-4 Radiation interference electric field strength Noise terminal voltage (EMS)EN61000-6-2 Static discharge immunity EMC RF electromagnetic field immunity EFT/B immunity Surge immunity Conductivity noise immunity Power frequency magnetic field immunity Voltage dip/Instantaneous stop/Voltage fluctuation immunity Dimensions • TH13 series Ⅺ52 Ⅺ2.047 • TH23 series Reset button RESET Ⅺ52 Ⅺ2.047 Rotary indicator 5 .197 Rotary indicator TH13·TH23 Pollution Degree 2/Overvoltage Category II EN55011 Group1 ClassA EN55011 Group1 ClassA EN61000-4-2 4 kV contact 8 kV air EN61000-4-3 10 V/m AM modulation (80 MHz to 1 GHz) 10 V/m pulse modulation (895 MHz to 905 MHz) EN61000-4-4 2 kV (power supply line) EN61000-4-5 1 kV (power line) EN61000-4-6 10 V/m AM modulation (0.15 MHz to 80 MHz) EN61000-4-8 30 A/m (50 Hz) EN61000-4-11 10 ms, 30% (rated voltage) 100 ms, 60% (rated voltage) 1,000 ms, 60% (rated voltage) 5,000 ms, 95% (rated voltage) mm inch General tolerance: ±1.0 ±.039 Mounting Case bracket (supplied) Decorative nut 46.8 1.843 4.75 .187 54 2.126 72 2.835 6 .236 No.187 quick connect terminal (4.75 × 6.0 × 0.5) (.187 × .236 × .020) (TH13 and TH23 series common) Wiring digram M Panel mounting Panel Case Mounting bracket (supplied) Decorative nut • Panel cutout dimensions 47 +0.5 −0.1 1.850 +.020 −.004 Operating power supply 5 .197 67 2.638 Replacing the TH13/23 series with the TH14/24 series The TH13/TH23 series hour meter are interchangeable with the TH14/24 series hour meter. Use the specified mounting frame because of a different setup method. It is advisable to introduce the TH14/24 series hour meters for the first time. DIN48 size and mounting frame setup Panel Mounting frame (sold separately): TH1400020 Ⅺ 52 Ⅺ 48 Ⅺ 47 Ⅺ 45 Mounting flame 167 .


TH2346 TH2356 TH2366


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)