Terminal Relay
Description
Terminal Relay
G6B-4@@ND
Compact Terminal Relay with 4 Independent Outputs
• Equipped with four G6B Mini-relays that are compact, highly sensitive, and highly resistant to dielectric surges, and that can switch 5 amps of power.
• Sealed plastic construction used for relays.
• Easy wiring with separated input/output terminals.
• Special P6B Mounting Socket used to facilitate maintenance
(except for high-reliability models).
• Standard models meet UL508 and CSA requirements.
• DIN Track mounting, and screw mounting models are available.
Model Number Structure
■ Model Number Legend
G6B-@@@@ND
12 3 Note: UL508 and CSA requirements met by standard models.
1.
Number of Poles
4: 4 poles (4PST-NO standard circuit) 47: 4 poles (4PST-NO long-life circuit) 48: 4 poles (4PST-NO high-reliability circuit)
Ordering Information
2.
Mounting None: DIN Track or screw mounting F: Screw mounting
3.
Input Terminal B: Phillips screw (3.
5 mm) terminals (4 independent points) B1: Flat-bladed screw terminals (4 points with same common) P: Connector terminals (4 independent points)
■ List of Models
Classification
Equipped with operation indicator and diode to absorb coil surge
Contact form 4PST (standard)
4PST (long-life)
4PST (high reliability)
4PST (standard)
4PST (standard)
Mounting method DIN Track or screw mounting
DIN Track or screw mounting
DIN Track or screw mounting
Screw mounting
Screw mounting
Terminals Phillips screw terminal
Phillips screw terminal
Phillips screw terminal
Flat-bladed screw terminal Connector
Rated voltage
5 VDC 12 VDC 24 VDC
5 VDC 12 VDC 24 VDC
5 VDC 12 VDC 24 VDC
5 VDC 12 VDC 24 VDC
5 VDC 12 VDC 24 VDC
Model G6B-4BND G6B-47BND G6B-48BND G6B-4FB1ND G6B-4FPND
Note: 1.
For replacement relays, use relays with the same voltage specifications as the relays provided with the Terminal when it was purchased.
Longer operating life can be achieved by replacing the G6B-4@@ND with the G6B-1147P-FD-US.
2.
Standard models are also available without relays mounted...