40A Digital PoL DC-DC Converter
Description
www.
murata-ps.
com
OKDx-T/40-W12-xxx-C
40A Digital PoL DC-DC Converter Series
PRELIMINARY
Typical units
FEATURES
Small package: 30.
85 x 20.
0 x 8.
2 mm (1.
215 x 0.
787 x 0.
323 in) SIP: 33.
0 x 7.
6 x 18.
1 mm (1.
30 x 0.
30 x 0.
713 in)
0.
6 V - 3.
3 V output voltage range High efficiency, typ.
97.
2% at 5Vin, 3.
3Vout half
load Configuration and Monitoring via PMBus Synchonization & phase spreading Current sharing, Voltage Tracking & Voltage
margining MTBF 14.
2 Mh
PRODUCT OVERVIEW
Fully regulated For narrow board pitch applications (15 mm/0.
6 in) Non-Linear Response for reduction of decoupling cap.
Input under voltage shutdown Over temperature protection Output short-circuit & Output over voltage protection Remote control & Power Good Voltage setting via pin-strap or PMBus Configurable via Graphical User Interface ISO 9001/14001 certified supplier Highly automated manufacturing ensures quality
PART NUMBER STRUCTURE
OKD x - T / 40 - W12 - xxx - C
Digital Non-isolated PoL
Y = Surface Mount H = Horizontal Mount Through-Hole X = SIP
Trimmable Output Voltage Range
0.
6 - 3.
3Vdc
RoHS Hazardous Substance Compliance
C = RoHS-6 (does not claim EU RoHS exemption 7b – lead in solder)
Software Configuration Digits (001 is positive turn-on logic)
Maximum Rated Output Current in Amps
Input Voltage Range 4.
5-14Vdc
For full details go to www.
murata-ps.
com/rohs
www.
murata-ps.
com/support
PM
MDC_OKDx-T/40-W12-xxx-C.
A01.
D6 Page 1 of 40
ORDERING GUIDE
Model Number OKDY-T/40-W12-001-C OKDH-T/40-W12-001-C OKDX-T/40-W12-001-C
Output 0.
6-3.
3 V, 40 A/ 132 W
General Information
Reliability The failure rate () and mean time between failures (MTBF= 1/) is calculated at max output power and an operating ambient temperature (TA) of +40°C.
Murata Power Modules uses Telcordia SR-332 Issue 2 Method 1 to calculate the mean steady-state failure rate and standard deviation ().
Telcordia SR-332 Issue 2 also provides techniques to estimate the upper confidence levels of ...