(2R-5S Series) Gas Discharge Tubes
Description
ELECTRONICS
Circuit Protection System
Gas Discharge
Tubes
2R-5S Series
Specifications are subject to change without notice.
Please refer to http://www.
ruilon.
com for current information.
Gas Discharge Tubes - 2R-5S Series
GDT introduction:Gas discharge tubes (GDT) use noble gasses enclosed in ceramic tubes to provide an alternate circuit path for voltage spikes.
The ceramic envelope and with nickel connectors allow for high loads and Ruilon offers products that function at 20KA,40KA,50KA,60KA,100KA&150KA.
The breakdown voltages of the devices have a wide range (up to 20% tolerance).
Major applications are high frequency telecommunication lines,stations, security systems,HID and high quality Surge Protection Devices (SPD).
Features
1.
RoHS & HF compliant 2.
SMD Structure 3.
DC Spark-over voltage: 75~1000V 4.
Low Capacitance 5.
Agency Recognition : UL/ cUL 6.
Operating temperature:-30°C ~ +85°C Storage
temperature:-40°C ~ +115°C
Recommended Applications
1.
Cable Modem 2.
xDSL 3.
Set-Top Box 4.
TV sets 5.
Power supplier 6.
Consumer electronics
Part Number Code
2R0
7
5
Series
DC Line Voltage
-5 Dimensions
Circuit Protection System
Specifications are subject to change without notice.
Please refer to http://www.
ruilon.
com for current information.
Page:1
Gas Discharge Tubes - 2R-5S Series
Electriacl Characteristics
Part No.
2R075-5S 2R090-5S 2R150-5S 2R230-5S 2R250-5S 2R300-5S 2R350-5S 2R400-5S 2R470-5S 2R600-5S 2R800-5S 2R1000-5S
DC Spark-over
Voltage
Maximum Impulse Breakdown Voltage
Max.
Impulse Discharge Current (8/20μs)
Impulse Life
(10/1000μs)
100V/S
100V/ 1KV/ 1 10 μS μs times times
100 A
(V)
(V) (V)
(KA)
Times
75±20% 600 700 5 3
300
90±20% 600 700 5 3
300
150±20% 500 700 5 3
300
230±20% 500 600 5 3
300
250±20% 500 600 5 3
300
300±20% 550 650 5 3
300
350±20% 600 700 5 3
300
400±20% 650 750 5 3
300
470±20% 750 850 5 3
300
600±20% 900 1000 5 3
300
800±20% 1000 1100 5 3
300
1000±20% 1500 1600 5 3
300
Normal Alternating D...