VOLTAGE DETECTOR
Description
S-19103/19109 Series
www.
ablic.
com © ABLIC Inc.
, 2014-2020
AUTOMOTIVE, 105°C OPERATION, 10 V, SENSE-INPUT VOLTAGE DETECTOR
Rev.
1.
3_00
The S-19103/19109 Series is a high-accuracy voltage detector developed using CMOS technology.
The detection voltage is fixed internally with an accuracy of ±3.
5% (−VDET(S) ≥ 2.
2 V).
The release voltage is set to the same value as the detection voltage, since there is no hysteresis width.
It operates with current consumption of 500 nA typ.
Apart from the power supply pin, the detection voltage input pin (SENSE pin) is also prepared, so the output is stable even if the SENSE pin falls to 0 V.
Two output forms Nch open-drain output and CMOS output are available.
ABLIC Inc.
offers FIT rate calculated based on actual customer usage conditions in order to support customer functional safety design.
For more information regarding our FIT rate calculation, contact our sales representatives.
Caution This product can be used in vehicle equipment and in-vehicle equipment.
Before using the product for these purposes, it is imperative to contact our sales representatives.
Features
• Detection voltage:
1.
0 V to 5.
0 V (0.
1 V step)
• Detection voltage accuracy:
±3.
5% (2.
2 V ≤ −VDET(S) ≤ 5.
0 V, Ta = −40°C to +105°C)
±(2.
5% + 22 mV) (1.
0 V ≤ −VDET(S) < 2.
2 V, Ta = −40°C to +105°C)
• Current consumption:
500 nA typ.
• Operation voltage range:
0.
95 V to 10.
0 V
• Output form:
Nch open-drain output (Active "L")
CMOS output (Active "L")
• Operation temperature range: Ta = −40°C to +105°C
• Lead-free (Sn 100%), halogen-free
• AEC-Q100 qualified*1
*1.
Contact our sales representatives for details.
Applications
• For automotive use (accessory, car navigation system, car audio system, etc.
)
Package
• SOT-23-5
1
AUTOMOTIVE, 105°C OPERATION, 10 V, SENSE-INPUT VOLTAGE DETECTOR
S-19103/19109 Series
Rev.
1.
3_00
Block Diagrams
1.
S-19103/19109 Series N type (Nch open-drain output)
SENSE
VDD
Function
Status
Output logic Active "L"
...
Similar Datasheet