FR101S THRU FR107S
FAST RECOVERY RECTIFIERS Reverse Voltage – 50 to 1000 Volts Forward Current – 1.0 Ampere
Features • High Current Capability • Fast switching for high efficiency • Exceeds Environmental Standards of MIL-S-19500/228 • 1 ampere operation at TA = 55oC with no thermal runaway • Low Leakage.
Mechanical Data • Case: Molded plastic, A-405 • Lead: Axial leads, solderable per MIL-STD-202, method 208 guaranteed. • Polarity: Color band denotes cathode end • Mounting Position: Any
Absolute Maximum Ratings and Characteristics
Ratings at 25℃ ambient temperature unless otherwise specified, single phase, half wave, 60Hz, resistive or inductive load, for capacitive load, derate current by 20%.
FR Symbols
101S
FR 102S
FR 103S
FR 104S
FR 105S
FR 106S
FR Units
107S
Maximum repetitive peak reverse voltage Maximum RMS voltage Maximum DC blocking voltage Average forward rectified current .375” (9.5mm) lead length at TA = 55 OC Peak forward surge current
VRRM VRMS VDC
I(AV)
50 100 200 400 600 800 1000 Volts 35 70 140 280 420 560 700 Volts 50 100 200 400 600 800 1000 Volts
1 Amp
8.3mS single half sine-wave superimposed on rated load (JEDEC method)
IFSM
30 Amps
Maximum forward voltage at 1A DC and 25oC
VF
1.3 Volts
Maximum reverse current
TA = 25℃
at rated DC blocking voltage
TA = 100℃
Maximum reverse recovery time (Note 1)
Typical junction capacitance (Note 2)
Typical thermal resistance (Note3)
Operating and storage temperature range
IR Trr CJ RΘJA TJ ,TS
5 500 150 250 12 67 -55 to +150
µA
500 nS pF
℃/W ℃
1) Reverse recovery test conditions: IF = 0.5A, IR = 1A, Irr = 0.25A.
2) Measured at 1MHZ and applied reverse voltage of 4 VDC .
3) Thermal resistance junction to ambient and form junction to lead at 0.375” (9.5mm) lead length P.C.B. mounted.
SEMTECH ELECTRONICS LTD.
(Subsidiary of Semtech International Holdings Limited, acompany
® listed on the Hong Kong Stock Exchange, Stock Code: 724)
Dated : 23/08/2004
.