Document
HD74LV05A
Hex Inverters with Open Drain Outputs
REJ03D0229–0700 Rev.7.00
Dec 23, 2005
Description
The HD74LV05A has six inverters with open drain outputs in a 14-pin package.
Low-voltage and high-speed operation is suitable for the battery-powered products (e.g., notebook computers), and the low-power consumption extends the battery life.
Features
• VCC = 2.0 V to 5.5 V operation
• All inputs VIH (Max.) = 5.5 V (@VCC = 0 V to 5.5 V)
• All outputs VO (Max.) = 5.5 V (@VCC = 0 V)
• All outputs VO (Max.) = 5.5 V (@VCC = 2.0 V to 5.5 V, Output “Z” state)
• Typical VOL ground bounce < 0.8 V (@VCC = 3.3 V, Ta = 25°C)
• Output current: ±6 mA (@VCC = 3.0 V to 3.6 V), ±12 mA (@VCC = 4.5 V to 5.5 V) • Ordering Information
Part Name
Package Type
Package Code (Previous Code)
Package Abbreviation
HD74LV05AFPEL
SOP–14 pin(JEITA) PRSP0014DF-B FP
(FP–14DAV)
HD74LV05ARPEL
SOP–14 pin(JEDEC) PRSP0014DE-A RP
(FP–14DNV)
HD74LV05ATELL
TSSOP–14 pin
PTSP0014JA-B T
(TTP–14DV)
Note: Please consult the sales office for the above package availability.
Taping Abbreviation (Quantity)
EL (2,000 pcs/reel)
EL (2,500 pcs/reel)
ELL (2,000 pcs/reel)
Function Table
Note:
Input A L H
H: High level L: Low level Z: High impedance
Output Y Z L
Rev.7.00 Dec 23, 2005 page 1 of 7
HD74LV05A
Pin Arrangement
1A 1 1Y 2 2A 3 2Y 4 3A 5 3Y 6 GND 7
14 VCC 13 6A 12 6Y 11 5A 10 5Y 9 4A 8 4Y
(Top view)
Absolute Maximum Ratings
Item
Symbol
Ratings
Unit Conditions
Supply voltage range Input voltage range*1 Output voltage range*1, 2
VCC VI VO
Input clamp current
Output clamp current
Continuous output current
Continuous current through VCC or GND Maximum power dissipation at Ta = 25°C (in still air) *3
IIK IOK IO ICC or IGND
PT
–0.5 to 7.0 –0.5 to 7.0 –0.5 to VCC + 0.5 –0.5 to 7.0
–20 ±50 ±25 ±50
785 500
V V V Output: L
VCC: OFF or Output: Z mA VI < 0 mA VO < 0 mA VO = 0 to VCC mA
mW SOP TSSOP
Storage temperature
Tstg –65 to 150 °C
Notes: The absolute maximum ratings are values, which must not individually be exceeded, and furthermore, no two of which may be realized at the same time.
1. The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
2. This value is limited to 7.0 V maximum.
3. The maximum package power dissipation was calculated using a junction temperature of 150°C.
Rev.7.00 Dec 23, 2005 page 2 of 7
HD74LV05A
Recommended Operating Conditions
Item
Symbol
Min
Supply voltage range
VCC 2.0
Input voltage range
VI 0
Output voltage range
VO 0
Output current
IOL —
—
—
—
Input transition rise or fall rate
∆t / ∆v
0
0
0
Operating free-air temperature
Ta –40
Note: Unused or floating inputs must be held high or low.
Logic Diagram
Max 5.5 5.5 5.5 50 2 6 12 200 100 20 85
A
Unit V V V µA mA
ns/V
°C
Conditions
VCC = 2.0 V VCC = 2.3 to 2.7 V VCC = 3.0 to 3.6 V VCC = 4.5 to 5.5 V VCC = 2.3 to 2.7 V VCC = 3.0 to 3.6 V VCC = 4.5 to 5.5 V
Y
DC Electrical Characteristics
Ta = –.