Sensing element/Gauge
FPN,FGN-6 Data sheet
Features
. Dual-In-line-Package (DIP)or SMD, Easy to mount on PCB . Vacuum pressure measurable
Applications
. Home use Non-Invasive Blood Pressure(NIBP)monitors . Vacuum cleaner . Washing machine
Part number for ordering
FGN - 6 07P G S R
Model FPN FGN
Rated pressure
(PSI)
Length of the pressure port
(FGN only) 6 : 6mm
Pressure type G : Gauge
Terminal leads direction(See Outline Diagram) No mark :
R: Terminal leads configuration No mark : DIP(FPN) S : Surface mount package(FGN)
Pressure type
FPN
Gauge pressure
FGN-6
Model
Package configuration
Dual-In-line-Package(DIP)
Surface mount package, 6mm pressure port
Measurable pressure range(kPa) 13.79 13.79 34.47 34.47 48.26 48.26 98.07 103.4
FPN-02PG FPN-05PG FPN-07PG FPN-15PG
Part number for ordering FPN-02PGR FPN-05PGR FPN-07PGR FPN-15PGR
Specifications
Model/Rated pressure
02PG
05PG
07PG
Recommended operating conditions
Pressure type
Gauge pressure
Rated pressure
13.79 0.141
34.47 0.352
48.26 0.492
Measurable pressure range
13.79 13.79
34.47 34.47
48.26 48.26
Pressure media
Non-corrosive gas
Excitation current(Constant)
1.5
Absolute maximum rating
Maximum load pressure
Twice of rated pressure
Maximum excitation current
3.0
Operating temperature
0 80
Storage temperature
20 100
Operating humidity
30 80(No dew condensation)
Electric performances/characteristics(Excitation current I=1.5mA constant, Ambient temperature Ta=25
Full scale span voltage
40 130
Offset voltage
40
25
Bridge impedance
4000 6000
Mechanical response time
2(For the reference)
Accuracy
Temperature sensitivity of offset(TSO)
10.0
8.0
Temperature coefficient of sensitivity(TCS)
5.0
2.5
Linearity
0.6
0.3
Pressure hystersis
1.0
0.7
)
FGN-602PGSR FGN-605PGSR FGN-607PGSR FGN-615PGSR
15PG
103.4 1.055 98.07 103.4
unit
kPa kg/cm2
kPa
mADC
mADC
RH
mV mV
msec FS/0 50 FS/0 50
FS FS
1
Sensing element/Gauge
Outline dimensions
FPN
12 6 54
14
123 Labelled faceplate
60 0.5
1.2 2.54 2.54
15.24(600mil)
FPN,FGN-6 Data sheet
48 2.2
R1.5
0.25 max 15
Pressure port 0.8
0.6 Vent hole
4.5 456
unit(mm)
3
Terminal leads
6.8 2.8
C0.5
321
Recommended footprint for PCB
6- 0.9(Diameter of through holes) 6- 1.8(Diameter of lands)
2.54 2.54
15.2
unit(mm)
1.2 0.5
60 2.54 2.54
14 max 15 0.25
FPN-R
12 654
123 Labelled faceplate
48 2.2
R1.5
0.8 Pressure port
456
unit(mm)
3 15.24(600mil)
C0.5 Terminal leads
2.8 6.8
0.6 Vent hole
321 4.5
Recommended footprint for PCB
6- 0.9(Diameter of through holes) 6- 1.8(Diameter of lands)
2.54 2.54
15.2 unit(mm)
2
Sensing element/Gauge
Outline dimensions
FGN-6
Pressure port
2.54 2.54 0.8
1 23
FPN,FGN-6 Data sheet
unit(mm)
17
Vent hole
654 7
Index
0.8
15 MAX.
Projections
10.3
Labelled faceplate 6 5 4
2-R0.5
Projections 1 2 3
0.25
3
0.5 3.5 6 9.5
Recommended footprint for PCB
2- 1(Holes for projections) 1.7
1.4
2.54 2.54 6.2
Land-pads
6.2 9.4
unit(mm)
Connection diagram
FPN, FGN-6
i 1.5mA
Constant current source
2
R2 3
R3
R1 R4
1 6
Output voltage
1 5 VR0
6 Zero balancing trimmer (VR0) is available. VR0: 200
Note ; Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice.
If you have any questions regarding technical issues or specifications, please contact us.
Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan
Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538 E-mail :
[email protected]
3
unit(mm)
.