DatasheetsPDF.com

6SL3131-7TE31-2AA3 Dataheets PDF



Part Number 6SL3131-7TE31-2AA3
Manufacturers Siemens
Logo Siemens
Description Active Line-Module
Datasheet 6SL3131-7TE31-2AA3 Datasheet6SL3131-7TE31-2AA3 Datasheet (PDF)

© Siemens AG 2007 SINAMICS S120 drive system Booksize format for Line and Motor Modules Active Line Modules in booksize format ■ Overview ■ Design (continued) The scope of supply of the Active Line Modules includes: • DRIVE-CLiQ cable for connection to the Control Unit for drive control on the immediate left • DRIVE-CLiQ cable (length depends on module width) to connect Active Line Module to adjacent Motor Module • 2 blanking plugs for sealing unused DRIVE-CLiQ sockets • Jumper for connecting.

  6SL3131-7TE31-2AA3   6SL3131-7TE31-2AA3



Document
© Siemens AG 2007 SINAMICS S120 drive system Booksize format for Line and Motor Modules Active Line Modules in booksize format ■ Overview ■ Design (continued) The scope of supply of the Active Line Modules includes: • DRIVE-CLiQ cable for connection to the Control Unit for drive control on the immediate left • DRIVE-CLiQ cable (length depends on module width) to connect Active Line Module to adjacent Motor Module • 2 blanking plugs for sealing unused DRIVE-CLiQ sockets • Jumper for connecting the 24 V DC busbar to the adjacent Motor Module • 24 V terminal adapter • Connector X21 for digital inputs • Fan insert for the 80 kW (100 HP) and 120 kW (150 HP) Active Line Modules is supplied with the modules. The voltage for the fan insert is supplied by the Active Line Module. • 1 set of warning signs in foreign languages ■ Integration The self-commutated feed/feedback units (with IGBTs in infeed and regenerative feedback directions) generate a regulated DC link voltage. This means that the connected Motor Modules are decoupled from the line voltage. Line voltage fluctuations within the permissible supply tolerances have no effect on the motor voltage. Active Line Modules are designed for connection to grounded-neutral (TN, TT) and non-grounded (IT) supply systems. The Active Line Module communicates via DRIVE-CLiQ with the CU320 Control Unit, SINUMERIK 802D sl, SINUMERIK 840D sl with NCU 710.1/NCU 720.2/NCU 730.1/ NCU 730.2 PN or with the Numeric Control Extensions NX10/NX15 and receives its control information from these sources. The DC link is pre-charged via integrated precharging resistors. In order to operate an Active Line Module, it is absolutely essential to use the appropriate Active Interface Module or matching line reactor. ■ Design The Active Line Modules in booksize format feature the following interfaces as standard: • 1 line connection via screw-type terminals • 1 connection for the 24 V DC electronics power supply via the 24 V terminal adapter included in the scope of supply • 1 DC link connection via integrated DC link busbars • 3 DRIVE-CLiQ sockets • 2 PE (protective earth) connections 9 The status of the Active Line Modules is indicated via two multi-color LEDs. On the 100 mm (3.94 in) wide Active Line Module, the shield for the power supply cable can be connected to the integrated shield connection plate via a shield connection terminal or tube clip, e.g. Weidmüller type KLBÜ CO 4. The shield connection terminal must not be used for strain relief. Shield connection plates are available for the 150 mm (5.91 in), 200 mm (7.87 in) and 300 mm (11.81 in) wide modules. The signal cable shield can be connected to the Line Module by means of a shield connection terminal, e.g. type KLBÜ 3-8 SC by Weidmüller. Siemens NC 61 · 2007/2008 9/35 © Siemens AG 2007 SINAMICS S120 drive system Booksize format for Line and Motor Modules Active Line Modules in booksize format ■ Technical specifications General technical specifications General technical specifications (continued) Line connection voltage Up to 2000 m (6562 ft) above sea level Line frequency Power factor 380 ... 480 V 3 AC ± 10% (-15% < 1 min) 47 … 63 Hz Type of cooling Internal air cooling, power units with increased air cooling provided by integrated fan Built-on fan (with 80 kW (100 HP) and 120 kW (150 HP) Active Line Modules). • Active mode - Fundamental power factor (cos ϕ1) - Total (λ) • Smart mode - Fundamental mode - Total DC link voltage Vd 1.0 (factory setting), can be altered by input of a reactive current setpoint 1.0 (factory setting) > 0.96 0.65 … 0.90 In Active Mode, the DC link voltage is regulated and can be adjusted as a voltage decoupled from the line voltage. In Smart Mode, the DC link voltage is regulated in proportion to the line voltage to the mean rectified line voltage value. Factory setting for DC link voltage: 380 ... 400 V 3 AC: 600 V (Active Mode) 400 ... 415 V 3 AC: 625 V (Active Mode) 416 ... 480 V 3 AC: 1.35 x line voltage (Smart Mode) Permissible ambient or coolant temperature (air) in operation for line-side components, Line Modules and Motor Modules Installation altitude Conformity Approvals 0 ... 40 °C (32 ... 104 °F) without derating, > 40 ... 55 °C (104 ... 131 °F), see derating characteristics Up to 1000 m (3281 ft) above sea level without derating, > 1000 ... 4000 m (3281 ... 13124 ft) above sea level, see derating characteristics CE (low-voltage and EMC directives) cULus (File No.: E192450) Electronics power supply 24 V DC -15%/+20% Radio interference suppression • Active Line Module 16 kW (18 HP) and 36 kW (40 HP) - Standard (Active Line Module + no radio interference suppression line reactor) - with line filter package Class A1 to EN 55011 and Category C2 to EN 61800-3 • Active Line Module 55 kW (60 HP), 80 kW (100 HP) and 120 kW (150 HP) - Standard (Active Line Module + Category C3 to EN 61800-3 up to Act.


6SL3131-7TE28-0AA3 6SL3131-7TE31-2AA3 SKL12


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)