CT UNITE COMMUNICATION ECHNOLOGY LTD
SPECIFICATIONS
The information contained herein is the exclusive property of ZK and shall not be distribwritten permission of ZK
Version:V2.0 Date:2014.01.10 MODEL NAME: ZK7632 PRODUCT NAME :2T2R300Mbps,24G+5G+BT4.0 Wi-Fi Module
DESIGN:
CHECK:
Tel:86-755-61617105 Fax:86-755-61617110
Mobile:13926580539 E-mail::
[email protected] Add:6C
────────────────────────
:!
APPROVAL:
CT UNITE COMMUNICATION ECHNOLOGY LTD
DOCUMENT No :
REG.DATE :2014.01.10 REV.DATE :2014.01.10
SPECIFICATION MODEL NAME: ZK-7632
REV.NO : 1.5 PAGE :2/11
1. Features
ZK-7632 is the small size and low power module for IEEE 802.11a/b/g/n wireless LAN. ZK-7632 is based on MT7632 solution. IEEE802.11 a/b/g/n Dual Band WLAN infrastructure Size : 26.9mm x 13mm x 2.4mm 2.4GHz&5GHZ internal PA Two stream spatial multiplexing up to 867/300Mbps ANT (2T2R) Use on-chip OTP (One-Time Programmable) MT7632 USB 2.0 USB/WiFi 2.0 USB/Bluetooth V4.0 Low energy(LE) Supports drivers for Windows Vista, 2000, XP, Linux Security : WPA,WPA2,AES(TKIP) ,IEEE 802.1X • Application: DTV, DVR, HD DVD Player, Blue-ray Disk Player, STB
2. Ordering Information
Model ZK-7632
Description Wi-Fi Module, 2TR
3. Label markin
① ZK-7632 1111A0201 ②
④ :
③ 004TB5B00331
④ ① Model No
④ Product Lot No. : 1110A0401
② MAC Address BAR Code
-11 : Year
- 02 : Date
③ MAC Address No.
- 11: Month
- 01 : Manufactured
- Revision No. : A
Process
CT UNITE COMMUNICATION ECHNOLOGY LTD
REG.DATE :2014.01.10 REV.DATE :2014.01.10
SPECIFICATION MODEL NAME : ZK-7632
4. Block Diagram
DOCUMENT No :
REV.NO : 1.5 PAGE : 3/11
< Fig.1 Hardware Block Diagram >
5. Absolute Maximum Ratings
Caution : The specifications in Table 1 define levels at which permanent damage to
the device can occur. Function operation is not guaranteed under these conditions.
Operating at absolute maximum conditions for extend periods can adversely affect the
long-term reliability of the device.
Parameter
Min Max Unit
Storage Temperature
-10
+80℃
℃
Storage Humidity (40℃ )
-
90% %
< Table 1 Absolute Maximum Ratings > . Other conditions 1) Do not use or store modules in the corrosive atmosphere, especially where chloride gas, sulfide gas, acid, alkali, salt or the like are contained. Also, avoid exposure to moisture.
2) Store the modules where the temperature and relative humidity do not exceed 5 to 40℃ and 20 to 60%.
3) Assemble the modules within 6 months. Check the soldering ability in case of 6 months over.
CT UNITE COMMUNICATION ECHNOLOGY LTD
REG.DATE :2014.01.10 REV.DATE :2014.01.10
SPECIFICATION MODEL NAME : ZK-7632
DOCUMENT No :
REV.NO : 1.5 PAGE : 4/11
5. Operating Conditions
Parameter
Operating Temperature
Operating Humidity
Supply Voltage1
VDD_3.3V
Min Typ Max Unit 0 - 100 ℃ - - 130 % 2.7 3.3 4.0 Vdc
6. Standard Test Conditions
The Test for electrical specification shall be performed under the following condition unless otherwise specified.
1). Ambient condition Temper.