DatasheetsPDF.com

CIC61508 Dataheets PDF



Part Number CIC61508
Manufacturers Infineon Technologies
Logo Infineon Technologies
Description Safety Monitor
Datasheet CIC61508 DatasheetCIC61508 Datasheet (PDF)

CIC61508 Safety Monitor User's Manual R e l e a s e v2.2 Microcontrollers Edition Nov 2012 Published by Infineon Technologies AG 81726 München, Germany © Infineon Technologies AG 2012. All Rights Reserved. Legal Disclaimer The information given in this document shall in no event be regarded as a guarantee of conditions or characteristics (―Beschaffenheitsgarantie‖). With respect to any examples or hints given herein, any typical values stated herein and/or any information regarding the applicat.

  CIC61508   CIC61508


Document
CIC61508 Safety Monitor User's Manual R e l e a s e v2.2 Microcontrollers Edition Nov 2012 Published by Infineon Technologies AG 81726 München, Germany © Infineon Technologies AG 2012. All Rights Reserved. Legal Disclaimer The information given in this document shall in no event be regarded as a guarantee of conditions or characteristics (―Beschaffenheitsgarantie‖). With respect to any examples or hints given herein, any typical values stated herein and/or any information regarding the application of the device, Infineon Technologies hereby disclaims any and all warranties and liabilities of any kind, including without limitation warranties of non-infringement of intellectual property rights of any third party. Information For further information on technology, delivery terms and conditions and prices please contact your nearest Infineon Technologies Office (www.infineon.com). Warnings Due to technical requirements components may contain dangerous substances. For information on the types in question please contact your nearest Infineon Technologies Office. Infineon Technologies Components may only be used in life-support devices or systems with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure of that life-support device or system, or to affect the safety or effectiveness of that device or system. Life support devices or systems are intended to be implanted in the human body, or to support and/or maintain and sustain and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may be endangered. Safety Monitor CIC61508 Date 2010-10-21 2010-11-08 2010-11-09 2010-11-09 2010-11-12 2010-11-15 2010-11-17 2010-11-17 2010-11-26 2010-12-10 2011-01-19 Version 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 0.94 1.0 2011-03-22 2011-03-23 2011-03-24 2011-03-25 2011-04-11 2011-04-21 2012-01-18 2012-04-24 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 2012-05-28 1.9 2012-05-29 User's Manual 2.0 Document Change History Changed By Change Description Viswanath.R Initial Version Viswanath.R Modules prepared Introduction, Error State Monitor, Voltage Monitor and Task Monitor Viswanath.R Opcode test sequencer is added Viswanath.R, Bharatesh Updated all the sections Viswanath.R, Bharatesh Viswanath.R, Bharatesh Added acronyms and the abbreviations and edited all the sections. updated as per Daryl‘s comments Viswanath.R, Bharatesh Added the application use case Viswanath.R Modified with the proper page breaks and with proper formats Ashish K Incorporated review comments from Mike Beach and Christophe Bouquet M. Beach/A. Wenlock Proofing and minor additions Ashish K Modified Cover Page Template and updated the formula in Section 2.6.3 Added disclaimer for customization of DFLASH configuration Ashish K Removed some confusing terms like ―opcode test sequencer‖ and replaced them with standard terms Ashish K Review comments incorporated. Update with respect to usage of TARDISS tool. M Beach Review and minor reformatting M. Beach/A. Wenlock Proofing Bharatesh Corrected SYSDISA, SYSDISB parameters in section 2.7.1 Bharatesh Updated section 2.3.1 - SPI Communication Protocol Bharatesh UTP AI00064054: Added section 5.1 Selecting CIC61508 system clock frequency Bharatesh Incorporated review comment of REV_003314. Added section 5.1 Selecting CIC61508 system clock frequency. Updated sections 2.1.1.1 - ROM / PFLASH checksum check. 2.2.1 – Correction of CIC state. 2.3.2 - SPI Error Handling. 2.6.1 - Wake-up Timer Operation, 2.6.3 - Wake-up Timer calibration. 3 - Tuning the DFLASH NVM Configuration. Bharatesh UTP AI00064054:Updated section 2.3 SPI. Added 7 - Configuration guidelines Arjun Muddaiah Updated the Table 7 in section 2.3.2 3 Release v2.2, Nov 2012 Safety Monitor CIC61508 Date Version 2012-07-10 2012-11-26 2.1 2.2 Document Change History Changed By Change Description with worst case leading and trailing delay. Arjun Muddaiah UTP AI00061900: Updated section 2.2.1 - Error Counters Arjun Muddaiah UTP AI00127297: Updated the UM to follow the proper naming conventions for Error State Monitor module. We Listen to Your Comments Is there any information within this document that you feel is wrong, unclear or missing? Your feedback will help us to continuously improve the quality of this document. Please send your comments (including a reference to this document) to: mailto:[email protected] Thank you. User's Manual 4 Release v2.2, Nov 2012 Safety Monitor CIC61508 Table of Contents Page 1 1.1 1.2 1.2.1 1.2.2 1.3 1.4 1.5 1.6 1.7 1.8 Introduction ...................................................................................................................................9 Scope ..............................................................................................................................................9 Acronyms, Abbreviations and.


MMSZ4716-V CIC61508 HT6808


@ 2014 :: Datasheetspdf.com :: Semiconductors datasheet search & download site.
(Privacy Policy & Contact)