Document
015AZ2.0~015AZ12
TOSHIBA Diode Silicon Epitaxial Planar Type
015AZ2.0~015AZ12
Constant Voltage Regulation Applications
Unit: mm
l Small package l Nominal voltage tolerance about ±2.5%
(2.0V~12V)
Maximum Ratings (Ta = 25°C)
Characteristics
Symbol
Rating
Power dissipation
P* 150
Junction temperature
Tj 125
Storage temperature range
Tstg -55~125
* Mounted on a glass epoxy circuit board of 20 × 20mm, Pad dimension of 4 × 4mm.
Unit
mW °C °C
Electrical Characteristics
(See Page 2~3)
JEDEC JEITA TOSHIBA Weight: 1.4 mg
― ― 1-1G1A
Marking
Example 1: 015AZ12-×
Example 2: 015AZ12-×
Pin Assignment (top view)
1 2001-10-30
015AZ2.0~015AZ12
Electrical Characteristics (Ta = 25°C)
Zener Voltage
Dynamic Impedance
Knee Dynamic Impedance
Reverse Current
Type No.
* VZ (V) Min Max
IZ (mA)
ZZ(Ω) Max
015AZ2.0 **
X Z
015AZ2.2 **
X Z
015AZ2.4
X Z
015AZ2.7
X Z
015AZ3.0
X Z
015AZ3.3
X Z
015AZ3.6
X Z
015AZ3.9
X Z
X
015AZ4.3
Y
Z
X
015AZ4.7
Y
Z
X
015AZ5.1
Y
Z
X
015AZ5.6
Y
Z
X
015AZ6.2
Y
Z
X
015AZ6.8
Y
Z
* : Test time: t = 30ms ** : Product by order.
1.85 1.95 2.05 2.16 2.28 2.40 2.50 2.65 2.80 2.95 3.10 3.25 3.40 3.55 3.70 3.87 4.00 4.13 4.25 4.40 4.53 4.66 4.80 4.97 5.14 5.30 5.43 5.61 5.80 6.00 6.19 6.40 6.60 6.82
2.05 2.15 2.26 2.38 2.50 2.60 2.75 2.90 3.05 3.20 3.35 3.50 3.65 3.80 3.97 4.10 4.23 4.35 4.50 4.63 4.76 4.90 5.07 5.24 5.40 5.63 5.81 6.00 6.20 6.39 6.60 6.80 7.02 7.20
5 5 5 5 5 5 5 5 5
5
5
5
5
5
100 100 100 110 120 130 130 130 130
120
70
40
30
25
IZ (mA)
ZZK(Ω) Max
IZ (mA)
IR (mA) Max
5
1000
0.5
120
5
1000
0.5
120
5
1000
0.5
120
5
1000
0.5
120
5
1000
0.5
50
5
1000
0.5
20
5
1000
0.5
10
5
1000
0.5
10
5
1000
0.5
5
5
1000
0.5
5
5
1000
0.5
1
5 900 0.5 1
5 500 0.5 1
5 150 0.5 0.5
VR (V) 0.5 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
1.0
1.5
2.5
3.0
5.0
2 2001-10-30
015AZ2.0~015AZ12
Electrical Characteristics (Ta = 25ºC)
Zener Voltage
Type No.
* VZ (V) Min Max
IZ (mA)
X
015AZ7.5
Y
Z
X
015AZ8.2
Y
Z
X
015AZ9.1
Y
Z
X
015AZ10
Y
Z
X
015AZ11
Y
Z
X
015AZ12
Y
Z
* : Test time: t = 30ms
7.00 7.43 7.23 7.66 7.46 7.90 7.70 8.16 7.96 8.43 8.23 8.70 8.50 9.00 8.80 9.30 9.10 9.60 9.40 9.93 9.73 10.26 10.06 10.60 10.40 10.98 10.73 11.26 11.06 11.60 11.40 11.93 11.73 12.26 12.06 12.60
5 5 5 5 5 5
Dynamic Impedance
ZZ(Ω) Max
IZ (mA)
23 5
20 5
18 5
15 5
15 5
15 5
Knee Dynamic Impedance
ZZK (Ω) Max
IZ (mA)
120 0.5
120 0.5
120 0.5
120 0.5
120 0.5
110 0.5
Reverse Current
IR (mA) Max
VR (V)
0.5 6.0
0.5 6.5
0.5 7.0
0.5 8.0
0.5 8.5
0.5 9.0
3 2001-10-30
015AZ2.0~015AZ12
4 2001-10-30
015AZ2.0~015AZ12
5 2001-10-30
015AZ2.0~015AZ12
RESTRICTIONS ON PRODUCT USE
000707EAA
· TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or damage to property. In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability Handbook” etc..
· The TOSHIBA products listed in this document are intended for usage in general electronics applications (computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this document shall be made at the customer’s own risk.
· The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by TOSHIBA CORPORATION for any infringements of intellectual property or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any intellectual property or other rights of TOSHIBA CORPORATION or others.
· The information contained herein is subject to change without notice.
6 2001-10-30
.